background image

171 505 41  07-01

   

Gph

18

19

20

21

kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h

1,00

4,99

59

51

5,13

61

52

5,26

62

54

5,40

64

55

1,10

5,49

65

56

5,64

67

57

5,79

69

59

5,93

70

60

1,20

5,99

71

61

6,16

73

63

6,32

75

64

6,47

77

66

1,25

6,24

74

64

6,41

76

65

6,58

78,

67

6,74

80

69

1,35

6,74

80

69

6,93

82

71

7,11

84

72

7,28

86

74

1,50

7,48

89

76

7,69

91

78

7,89

93

80

8,08

96

82

1,65

8,24

98

84

8,47

100

86

8,69

103

89

8,90

105

91

1,75

8,78

104

90

8,98

106

92

9,21

109

94

9,44

112

96

2,00

9,99

118

102

10,26

122

105

10,53

125

107

10,79

128

110

2,25

11,24

133

115

11,55

137

118

11,85

140

121

12,14

144

124

2,50 12,48

148

127

12,83

152

131

13,16

156

134

13,49

160

138

2,75 13,73

163

140

14,11

167

144

14,48

171

148

14,84

176

151

3,00 14,98

178

153

15,39

182

157

15,79

187

161

16,18

192

165

3,50 17,48

207

178

17,96

213

183

18,43

218

188

18,89

224

193

4,00 19,98

237

204

20,53

243

209

21,06

250

215

21,59

256

220

4,50 22,47

266

229

23,09

274

235

23,69

281

242

24,28

288

248

5,00 24,97

296

255

25,65

304

262

26,33

312

268

26,98

320

275

5,50 27,47

326

280

28,22

335

288

28,96

343

295

29,68

352

303

6,00 29,97

355

306

30,79

365

314

31,59

374

322

32,38

384

330

6,50 32,46

385

331

33,35

395

340

34,22

406

349

35,07

416

358

7,00 34,96

415

356

35,92

426

366

36,86

437

376

37,77

448

385

7,50 37,46

444

382

38,49

456

392

39,49

468

403

40,47

480

413

8,00 39,96

474

407

41,05

487

419

42,12

499

429

43,17

512

440

8,50 42,45

503

433

43,62

517

445

44,75

531

456

45,87

544

468

9,00 44,95

533

458

46,18

548

471

47,39

562

483

48,57

576

495

9,50 47,45

563

484

48,75

578

497

50,02

593

510

51,26

608

523

10,00 49,94

592

509

51,32

609

523

52,66

624

537

53,96

640

550

11,00 54,94

652

560

56,45

669

576

57,92

687

591

59,36

704

605

12,00 59,93

711

611

61,58

730

628

63,19

749

644

64,76

768

660

14,00 69,92

829

713

71,84

852

733

73,72

874

752

75,55

896

770

16,00 79,91

948

815

82,11

974

837

84,25

999

859

86,34

1024

880

NOZZLE TABLE

Pump pressure bar

The table applies to oil with a viscosity of 4,4 mm

2

/s (cSt) with density 830 kg/m

3

.

1(2)

Summary of Contents for Bentone B 45A2.2H

Page 1: ...Providing sustainable energy solutions worldwide 178 030 56 Installation and maintenance instruction B45A2 2H ...

Page 2: ......

Page 3: ...ge 2 15 Solenoid valves 16 Nozzle assembly adjustment 17 Connecting pipe pump adjustment device 18 Adjustment device Nozzle assembly adjustment 19 Fuse 20 Indicating lamp Stage 2 21 Switch I II 22 Indicating lamp Stage 1 23 Switch 0 I 24 Contactor 25 Control box 26 Drive coupling 27 Conical shield plate 28 Ignition electrodes 171 205 44 12 01 Components THE BURNERS MUST NOT BE FIRED WITHOUT FITTIN...

Page 4: ...and the spray pattern change with the pump pressure Output range and nozzles recommended The net caloriic value of 11 86 kWh kg for light oil has been used Length of burner tube Flange Measure B B45A2 270 238 B45A2 370 338 Oil capacity Capacity Recommended nozzle Recommended Pump pressure kg h kW Mcal h Angle Danfoss Monarch Bar B45A2 8 5 45 5 101 540 87 464 45 60 S B R PLP 14 bar Type designation...

Page 5: ...TECHNICAL DATA 171 225 34 09 01 Dimensions of lange 14 ø134 ø200 ø224 260 ...

Page 6: ...e an optimum adjust ment is obtained If larger nozzles are used the preadjustment of both the air volume and the nozzle assembly must be increased A whistling sound may be heard which can be eliminated or reduced as follows Increase the nozzle as sembly adjustment somewhat The CO2 contentandconsequentlytheair volume will then be reduced Oil supply The oil line should be dimensioned in accordance w...

Page 7: ...t stage Set the operating switch S2 on low capacity I Loosen the screw A and turn the damper to the position wan ted Tighten the screw A again Second stage Set the operating switch S2 on high capacity II Screw the knurled ring B in reduce or out increase The position of the damper can be read on the damper scale C Check the air adjustment by making a lue gas analysis ...

Page 8: ... and cut off the oil supply Service of burner head alt A Service of burner head alt B Note For maintenance of the brake plate nozzles electrodes etc when using a long design of the burner tube you havetoremovethenozzleassembly fromtheconnectingpipeandmove the assembly backwards in the fan housing from the boiler ...

Page 9: ...LMO24 LOA2 Wiring diagram ELECTRIC EQUIPMENT 171 435 27 15 01 1 3 If the boiler is not equipped with wired contacts connect the enclosed contacts to terminals X4 and X6 in accordance with wiring diagram 1N 50 60 Hz 230 V ...

Page 10: ...opens Oil mist is formed and ignited The photocell indicates a lame 3 The safety time expires a If no lame is established before this time limit the control cuts out b If for some reasons the lame disappears after this time limit the burner will make an attempt to re start 4 High Low thermostat ON The burner is in operating position and can now change between full load and low load 4 5 Operating p...

Page 11: ...e problem by pressing and holding the reset button for 3 seconds The number of lashes below is repeated with a pause in between 2 lashes No lame signal when safety time expires 4 lashes False light during start 7 lashes 3 x Losses of lame during operation 8 lashes Time out for preheater 10 lashes Incorrect wiring internal fault or si multaneousoccurrenceoftwofaults In order for this fault code to ...

Page 12: ...h in metres at a nozzle capacity of 9 5 Gph Max permissible pres sure at the suction and pressure side is 2 0 bar Components 1 Nozzle outlet G 1 8 Stage 2 2 Pressure gauge port G 1 8 3 Nozzle outlet G 1 8 Stage 1 4 Pressure gauge port G 1 8 5 Vacuum gauge port G 1 8 6 Return line G 1 4 and internal by pass plug 7 Suction line G 1 4 8 Return plug 9 Pressure adjustment 10 Solenoid valve 1 11 Solenoi...

Page 13: ...ic it is assured by a bleed lat on the piston In one pipe operation a high pressure connection must be loosened until the air is evacuated from the system Cut Off The solenoid valves of the A2L pump are of the normally closed type and are situated in the nozzle lines This design ensures extremely fast res ponse and the switching can be sel ected according to the burner opera ting sequence and is i...

Page 14: ... 93 9 71 115 99 10 24 121 104 10 73 127 109 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14 89 176 152 15 62 185 159 4 50 14 97 177 153 15 88 188 162 16 75 198 171 17 57 208 179 5 00 16 64 197 170 17 65 209 180 18 62 221 190 19 52 231 199 5 50 18 30 217 187 19 42 230 198 20 48 243 209 21 47...

Page 15: ...11 21 133 114 11 67 138 119 12 11 144 123 12 53 148 128 3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 97 201 173 17 62 209 180 18 23 216 186 4 50 18 35 217 187 19 10 226 195 19 82 235 202 20 51 243 209 5 00 20 39 242 208 21 22 251 216 22 03 261 225 22 79 270 232 5 50 22 43 266 229 23 34 277 238 24 23 ...

Page 16: ... 23 34 277 238 6 00 22 34 265 228 23 42 278 239 24 47 290 250 24 46 302 260 6 50 24 20 287 247 25 37 301 259 26 51 314 270 27 58 327 281 7 00 26 06 309 266 27 33 324 279 28 55 339 291 29 70 352 303 7 50 27 92 331 285 29 28 347 299 30 59 363 312 31 83 377 325 8 00 29 79 353 304 31 23 370 318 32 63 387 333 33 95 403 346 8 50 31 65 375 323 33 18 393 338 34 66 411 353 36 07 428 368 9 00 33 59 398 343 ...

Page 17: ... 70 317 272 6 00 26 43 313 270 27 49 326 280 28 27 335 288 29 13 345 297 6 50 28 63 340 292 29 63 351 302 30 62 363 312 31 55 374 322 7 00 30 84 366 314 31 91 378 325 32 98 391 336 33 98 403 374 7 50 33 04 392 337 34 19 405 349 35 33 419 360 36 41 432 371 8 00 35 25 418 359 36 47 433 372 37 69 447 384 38 80 460 396 8 50 37 45 444 382 38 74 459 395 40 04 475 408 41 26 489 421 9 00 39 65 470 404 41 ...

Page 18: ...59 256 220 4 50 22 47 266 229 23 09 274 235 23 69 281 242 24 28 288 248 5 00 24 97 296 255 25 65 304 262 26 33 312 268 26 98 320 275 5 50 27 47 326 280 28 22 335 288 28 96 343 295 29 68 352 303 6 00 29 97 355 306 30 79 365 314 31 59 374 322 32 38 384 330 6 50 32 46 385 331 33 35 395 340 34 22 406 349 35 07 416 358 7 00 34 96 415 356 35 92 426 366 36 86 437 376 37 77 448 385 7 50 37 46 444 382 38 4...

Page 19: ...23 56 279 240 4 50 24 85 295 253 25 41 301 259 25 96 308 265 26 49 314 270 5 00 27 61 327 282 28 24 335 288 28 84 342 294 29 44 349 300 5 50 30 38 360 310 31 06 368 317 31 73 376 324 32 38 384 330 6 00 33 14 393 338 33 89 402 346 34 62 411 353 35 33 419 360 6 50 35 90 426 366 36 70 435 374 37 49 445 382 38 26 454 390 7 00 38 56 457 393 39 53 469 403 40 38 479 412 41 21 489 420 7 50 41 42 491 422 4...

Page 20: ...of magnetic valve Burner fails to start Lamp not lit Motor runs Burner runs to lockout Fuse has blown Appliance thermostat has not reset Appliance overheat device has operated Control relay or photocell defective No oil being delivered Excessive lue draught is preventing lame establishment No spark Check or replace fuse if necessary Check reason for failure Adjust thermostat Reset overheat device ...

Page 21: ...ont conformes aux normes et aux documents normatifs suivants et satisfont aux critères applicables des directives CE suivantes Dokument EN 267 EN 60335 EU direktiv EU Directives EU Direktiven CE suivantes 2004 108 EC Elektromagnetisk kompatibilitet Electromagnetic compatibility EC Richtlinie Compatibilité électromagnétique 2006 95 EC Lågspänningsdirektivet Low voltage directive Niederspannungs Ric...

Page 22: ... the burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main switch is on If the burner starts but does not ignite Make an attempt to start the burner Never make close repeated start attempts Don t restart the burner until the boiler is free from oil gases If the burner stil...

Page 23: ......

Page 24: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com ...