background image

171 505 40  07-01

   

Gph

10

11

12

13

kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h

1,00

3,72

44

38

3,90

46

40

4,08

48

42

4,24

50

43

1,10

4,09

48

42

4,29

51

44

4,48

53

46

4,67

55

48

1,20

4,47

53

46

4,68

55

48

4,89

58

50

5,09

60

52

1,25

4,65

55

47

4,88

58

50

5,10

60

52

5,30

63

54

1,35

5,02

59

51

5,27

62

54

5,50

65

56

5,73

68

58

1,50

5,58

66

57

5,85

69

60

6,11

72

62

6,36

75

65

1,65

6,14

73

63

6,44

76

66

6,73

80

69

7,00

83

71

1,75

6,51

77

66

6,83

81

70

7,14

85

73

7,42

88

76

2,00

7,45

88

76

7,81

93

80

8,16

97

83

8,49

101

87

2,25

8,38

99

85

8,78

104

90

9,18

109

94

9,55

113

97

2,50

9,31

110

95

9,76

116

100

10,19

121

104

10,61

126

108

2,75 10,24

121

104

10,73

127

109

11,21

133

114

11,67

138

119

3,00

11,16

132

114

11,71

139

119

12,23

145

125

12,73

151

130

3,50 13,03

154

133

13,66

162

139

14,27

169

146

14,85

176

151

4,00 14,89

176

152

15,62

185

159

16,31

193

166

16,97

201

173

4,50 16,75

199

171

17,57

208

179

18,35

218

187

19,10

226

195

5,00 18,62

220

190

19,52

231

199

20,39

242

208

21,22

252

216

5,50 20,48

243

209

21,47

255

219

22,43

266

229

23,34

277

238

6,00 22,34

265

228

23,42

278

239

24,47

290

250

24,46

302

260

6,50 24,20

287

247

25,37

301

259

26,51

314

270

27,58

327

281

7,00 26,06

309

266

27,33

324

279

28,55

339

291

29,70

352

303

7,50 27,92

331

285

29,28

347

299

30,59

363

312

31,83

377

325

8,00 29,79

353

304

31,23

370

318

32,63

387

333

33,95

403

346

8,50 31,65

375

323

33,18

393

338

34,66

411

353

36,07

428

368

9,00 33,59

398

343

35,14

417

358

63,71

435

374

38,19

453

389

9,50 35,37

419

361

37,09

440

378

38,74

549

395

40,31

478

411

10,00 37,23

441

380

39,04

463

398

40,78

484

416

42,44

503

433

11,00 40,96

486

418

42,94

509

438

44,86

532

457

46,68

554

476

12,00 44,68

530

456

46,85

556

478

48,94

580

499

50,92

604

519

14,00 52,12

618

531

54,65

648

557

57,10

677

582

59,41

705

606

16,00 59,57

706

607

62,46

741

637

65,26

774

666

67,90

805

692

18,00 67,02

795

683

70,27

833

717

73,41

871

749

76,39

906

779

20,00 74,47

883

759

78,08

926

796

81,57

967

832

84,87

1007

865

22,00 81,91

971

835

85,89

1019

876

89,73

1064

915

93,36

1107

952

24,00 89,36

1060

911

93,70

1111

956

97,88

1161

998

101,85

1208

1039

26,00 96,81

1148

987

101,50

1204

1035

106,04

1258

1081

110,33

1308

1168

NOZZLE TABLE

Pump pressure bar

The table applies to oil with a viscosity of 4,4 mm

2

/s (cSt) with density 830 kg/m

3

.

1(2)

Summary of Contents for Bentone B 45A2.2H

Page 1: ...Providing sustainable energy solutions worldwide 178 030 56 Installation and maintenance instruction B45A2 2H ...

Page 2: ......

Page 3: ...ge 2 15 Solenoid valves 16 Nozzle assembly adjustment 17 Connecting pipe pump adjustment device 18 Adjustment device Nozzle assembly adjustment 19 Fuse 20 Indicating lamp Stage 2 21 Switch I II 22 Indicating lamp Stage 1 23 Switch 0 I 24 Contactor 25 Control box 26 Drive coupling 27 Conical shield plate 28 Ignition electrodes 171 205 44 12 01 Components THE BURNERS MUST NOT BE FIRED WITHOUT FITTIN...

Page 4: ...and the spray pattern change with the pump pressure Output range and nozzles recommended The net caloriic value of 11 86 kWh kg for light oil has been used Length of burner tube Flange Measure B B45A2 270 238 B45A2 370 338 Oil capacity Capacity Recommended nozzle Recommended Pump pressure kg h kW Mcal h Angle Danfoss Monarch Bar B45A2 8 5 45 5 101 540 87 464 45 60 S B R PLP 14 bar Type designation...

Page 5: ...TECHNICAL DATA 171 225 34 09 01 Dimensions of lange 14 ø134 ø200 ø224 260 ...

Page 6: ...e an optimum adjust ment is obtained If larger nozzles are used the preadjustment of both the air volume and the nozzle assembly must be increased A whistling sound may be heard which can be eliminated or reduced as follows Increase the nozzle as sembly adjustment somewhat The CO2 contentandconsequentlytheair volume will then be reduced Oil supply The oil line should be dimensioned in accordance w...

Page 7: ...t stage Set the operating switch S2 on low capacity I Loosen the screw A and turn the damper to the position wan ted Tighten the screw A again Second stage Set the operating switch S2 on high capacity II Screw the knurled ring B in reduce or out increase The position of the damper can be read on the damper scale C Check the air adjustment by making a lue gas analysis ...

Page 8: ... and cut off the oil supply Service of burner head alt A Service of burner head alt B Note For maintenance of the brake plate nozzles electrodes etc when using a long design of the burner tube you havetoremovethenozzleassembly fromtheconnectingpipeandmove the assembly backwards in the fan housing from the boiler ...

Page 9: ...LMO24 LOA2 Wiring diagram ELECTRIC EQUIPMENT 171 435 27 15 01 1 3 If the boiler is not equipped with wired contacts connect the enclosed contacts to terminals X4 and X6 in accordance with wiring diagram 1N 50 60 Hz 230 V ...

Page 10: ...opens Oil mist is formed and ignited The photocell indicates a lame 3 The safety time expires a If no lame is established before this time limit the control cuts out b If for some reasons the lame disappears after this time limit the burner will make an attempt to re start 4 High Low thermostat ON The burner is in operating position and can now change between full load and low load 4 5 Operating p...

Page 11: ...e problem by pressing and holding the reset button for 3 seconds The number of lashes below is repeated with a pause in between 2 lashes No lame signal when safety time expires 4 lashes False light during start 7 lashes 3 x Losses of lame during operation 8 lashes Time out for preheater 10 lashes Incorrect wiring internal fault or si multaneousoccurrenceoftwofaults In order for this fault code to ...

Page 12: ...h in metres at a nozzle capacity of 9 5 Gph Max permissible pres sure at the suction and pressure side is 2 0 bar Components 1 Nozzle outlet G 1 8 Stage 2 2 Pressure gauge port G 1 8 3 Nozzle outlet G 1 8 Stage 1 4 Pressure gauge port G 1 8 5 Vacuum gauge port G 1 8 6 Return line G 1 4 and internal by pass plug 7 Suction line G 1 4 8 Return plug 9 Pressure adjustment 10 Solenoid valve 1 11 Solenoi...

Page 13: ...ic it is assured by a bleed lat on the piston In one pipe operation a high pressure connection must be loosened until the air is evacuated from the system Cut Off The solenoid valves of the A2L pump are of the normally closed type and are situated in the nozzle lines This design ensures extremely fast res ponse and the switching can be sel ected according to the burner opera ting sequence and is i...

Page 14: ... 93 9 71 115 99 10 24 121 104 10 73 127 109 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14 89 176 152 15 62 185 159 4 50 14 97 177 153 15 88 188 162 16 75 198 171 17 57 208 179 5 00 16 64 197 170 17 65 209 180 18 62 221 190 19 52 231 199 5 50 18 30 217 187 19 42 230 198 20 48 243 209 21 47...

Page 15: ...11 21 133 114 11 67 138 119 12 11 144 123 12 53 148 128 3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 97 201 173 17 62 209 180 18 23 216 186 4 50 18 35 217 187 19 10 226 195 19 82 235 202 20 51 243 209 5 00 20 39 242 208 21 22 251 216 22 03 261 225 22 79 270 232 5 50 22 43 266 229 23 34 277 238 24 23 ...

Page 16: ... 23 34 277 238 6 00 22 34 265 228 23 42 278 239 24 47 290 250 24 46 302 260 6 50 24 20 287 247 25 37 301 259 26 51 314 270 27 58 327 281 7 00 26 06 309 266 27 33 324 279 28 55 339 291 29 70 352 303 7 50 27 92 331 285 29 28 347 299 30 59 363 312 31 83 377 325 8 00 29 79 353 304 31 23 370 318 32 63 387 333 33 95 403 346 8 50 31 65 375 323 33 18 393 338 34 66 411 353 36 07 428 368 9 00 33 59 398 343 ...

Page 17: ... 70 317 272 6 00 26 43 313 270 27 49 326 280 28 27 335 288 29 13 345 297 6 50 28 63 340 292 29 63 351 302 30 62 363 312 31 55 374 322 7 00 30 84 366 314 31 91 378 325 32 98 391 336 33 98 403 374 7 50 33 04 392 337 34 19 405 349 35 33 419 360 36 41 432 371 8 00 35 25 418 359 36 47 433 372 37 69 447 384 38 80 460 396 8 50 37 45 444 382 38 74 459 395 40 04 475 408 41 26 489 421 9 00 39 65 470 404 41 ...

Page 18: ...59 256 220 4 50 22 47 266 229 23 09 274 235 23 69 281 242 24 28 288 248 5 00 24 97 296 255 25 65 304 262 26 33 312 268 26 98 320 275 5 50 27 47 326 280 28 22 335 288 28 96 343 295 29 68 352 303 6 00 29 97 355 306 30 79 365 314 31 59 374 322 32 38 384 330 6 50 32 46 385 331 33 35 395 340 34 22 406 349 35 07 416 358 7 00 34 96 415 356 35 92 426 366 36 86 437 376 37 77 448 385 7 50 37 46 444 382 38 4...

Page 19: ...23 56 279 240 4 50 24 85 295 253 25 41 301 259 25 96 308 265 26 49 314 270 5 00 27 61 327 282 28 24 335 288 28 84 342 294 29 44 349 300 5 50 30 38 360 310 31 06 368 317 31 73 376 324 32 38 384 330 6 00 33 14 393 338 33 89 402 346 34 62 411 353 35 33 419 360 6 50 35 90 426 366 36 70 435 374 37 49 445 382 38 26 454 390 7 00 38 56 457 393 39 53 469 403 40 38 479 412 41 21 489 420 7 50 41 42 491 422 4...

Page 20: ...of magnetic valve Burner fails to start Lamp not lit Motor runs Burner runs to lockout Fuse has blown Appliance thermostat has not reset Appliance overheat device has operated Control relay or photocell defective No oil being delivered Excessive lue draught is preventing lame establishment No spark Check or replace fuse if necessary Check reason for failure Adjust thermostat Reset overheat device ...

Page 21: ...ont conformes aux normes et aux documents normatifs suivants et satisfont aux critères applicables des directives CE suivantes Dokument EN 267 EN 60335 EU direktiv EU Directives EU Direktiven CE suivantes 2004 108 EC Elektromagnetisk kompatibilitet Electromagnetic compatibility EC Richtlinie Compatibilité électromagnétique 2006 95 EC Lågspänningsdirektivet Low voltage directive Niederspannungs Ric...

Page 22: ... the burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main switch is on If the burner starts but does not ignite Make an attempt to start the burner Never make close repeated start attempts Don t restart the burner until the boiler is free from oil gases If the burner stil...

Page 23: ......

Page 24: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com ...

Reviews: