4
Bentone B 2
General
Important to think about!
Read this manual
• This manual should be taken into account by all who, for whatever
reason, work
with
the apparatus and associated system parts.
• This manual is aimed speciically at authorized personnel.
• This manual should be viewed as a part of the burner and should
always be kept close to the installation site.
• Enertech recommends that the burner be shut down
when the oil tank
is illed, and for six hours thereafter, to reduce the risk of blockages.
Safety instructions
The electrical installation must be carried out according to the high voltage
provisions and be performed in a professional manner, so that the risk of oil
leakage, ire or personal injury is avoided
Warning
• The manual must be read before installation and start-up.
• This manual should be followed by anyone who for any reason performs
work on the installation or its component parts.
• The manual is to be considered as part of the burner and must always
be kept in the vicinity of the installation site.
• Ensure that the fresh air inlet to the room where the burner is located is
always open.
• The burner may only be installed by authorized personnel.
• Check that the burner is suitable for the boiler type.
• The burner must be installed in accordance with local legislation
regarding electrical safety and fuel supply.
• The burner is designed for oil viscosities ranged between 1.2 and 8.0
cSt at 20°C.
• The burner must be protected by at most a 10 A fast-blow or 6.3 A
slow-blow fuse.
• No burner safety system may be disconnected.
• The installation engineer must ensure that the boiler room is supplied
with suficient fresh air in accordance with local standards.
• Cut the power and shut-off the fuel supply before performing service.
• Enertech recommends that the burner be shut down when the oil tank
is illed, and for six hours thereafter, to reduce the risk of blockages.
• The external temperature of the burner’s component parts may exceed
60°C.
• Ensure that the burner is protected from water spills, as its design will
not withstand such.
• Oil ilters should be used.
• Only use spare parts recommended by Enertech.
Warning
!
Summary of Contents for Bentone B 2 KA
Page 2: ......
Page 10: ...10 Bentone B 2 General 8 9 10 11 12 16 15 14 13 1 2 3 4 5 7 6 1 5 Description...
Page 32: ...32 Bentone B 2 General...
Page 33: ...33 Bentone B 2 General...
Page 34: ...34 Bentone B 2 General...
Page 35: ......
Page 36: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...