background image

After connecting, the terminals must be covered with grease as protection against 
corrosion.
The  specified  torque  loading  for  the  bolts/screws  of  the  end  cables  and 
connectors are:

The nominal operating battery temperature is 25°C. Higher temperatures shorten 
the life of the battery, lower temperatures reduce the available capacity. 55°C is 
the upper temperature limit and batteries should not be used above this operating 
temperature.  The  capacity  of  the  battery  changes  with  temperature  and  falls 
considerably under 0 °C. The optimum lifetime of the battery depends on the 
operating conditions (moderate temperature and discharges equal to or lower 
than 80% of the nominal capacity C5). The battery obtains its full capacity after 
about 10 charging and discharging cycles.

Vent plugs on the battery must not be sealed or covered. Electrical connections 
(e.g. plugs) must only be made or broken in the open circuit condition. To achieve 
the optimum life for the battery, operating discharges of more than 80%, of the 
rated capacity should be avoided (deep discharge).  

Rating Data

TM

Operation and maintenance instructions PerfectRail  DS batteries            

ENGLISH

1. Commissionning

2. Operation

2.1. Discharge

1. Nominal capacity C5

: See type 

2. Nominal voltage  

: See type 

3. Discharge current                   

: See type

4. Nominal SG. of electrolyte    

: 1.29 kg/l

5. Rated temperature                  

: 25°C

SAFETY PRECAUTIONS

ź

Pay attention to the operating instructions and keep 
them close to the battery. 

ź

Works on batteries must only be carried out by skilled 
personnel!

ź

Use protective glasses and wear safety clothing when 
working on batteries. 

ź

Adhere to the current accident prevention rules in the 
country where the battery is used or DIN EN 50272-3, 
DIN EN 50110-1.

ź

Keep children away from batteries!!

ź

No smoking!

ź

Do not expose batteries to naked flames, glowing embers 
or sparks, as it may cause the battery to explode.

ź

Avoid sparks from cables or electrical apparatus as well 
as electrostatic discharges. 

ź

Acid splashes into the eyes or on the skin must be 
washed immediately with an abundance of clean water. 
After abundant flushing consult a doctor immediately!

ź

Clothing contaminated by acid should be washed in 
water.

ź

Risk of explosion and fire

ź

Avoid short circuits: do not use non-insulated tools, do not 
place or drop metal objects on top of the battery. Remove 
rings, wristwatches and articles of clothing with metal parts 
that might come into contact with the battery terminals.

ź

Electrolyte is highly corrosive.

ź

Do not tip the battery over.

ź

Batteries and monoblocs are heavy. Ensure secure 
installation! Only use suitable handling equipment. Lifting 
hooks must not damage the blocs, connectors or cables.

ź

Do not place batteries in direct sunlight without protection.

ź

Discharged batteries can freeze. For that reason, always 
store in a frost-free zone.

ź

Dangerous electrical voltage!

ź

Pay attention to the hazards that can be caused by batteries

Ignoring the operating instructions, repair with non-original parts will render the warranty void.
All failures, malfunctions or defaults of the battery, the charger or any other accessories, must be notified to our After Sales Service.

The battery should be inspected to ensure it is in perfect physical condition. 

Check:
 

1. 

the battery cleanliness. Before installing the battery compartment has to be 
cleaned. 

2. 

the battery end cables have a good contact to terminals and the polarity 
is correct. Otherwise battery, vehicle or charger could be destroyed. 

3. 

the electrolyte level, the electrolyte level must 
always be above the top of the separators. 

Top up with demineralized water to the nominal level. Charge the battery (see 
2.2.2) before commissioning. Only blocs with the same state of discharge (the 
same voltage, tolerance as shown in the following table) should be connected 
together. 

 Rail engine starting flooded, flat plate, Pb-1.7%Sb/Pb-1.7%Sb 12V monoblocs 

Bloc voltage (V)

 

average value - 

Δ

U

bloc

Max. tolerance from 

 12 

± 0.049 

DIN conic post

8 ± 1 Nm

Reviews: