Quick Start Guide

Specifications

IMPORTANT:  

Not intended for use with 

life support equipment.

  

Contact Information

 Mailing  

17825 – 59

th

 Avenue NE

Address:

Suite B

Arlington, WA 98223 USA 

Web Site:

www.outbackpower.com

Date and Revision

April 2020, Revision A 

Audience

These instructions are for use by qualified personnel who meet all local and governmental code requirements 
for licensing and training for the installation of electrical power systems with AC and DC voltage up to 600 volts.  
Failure to install or use this equipment as instructed in the literature can result in damage to the equipment that 
may not be covered under the limited warranty.  This product is only serviceable by qualified personnel.

Product

The Rapid Shutdown Initiator (RSI) initiates the rapid shutdown function
required for a PV array with module-level power electronics (MLPE) and other 
devices, as part of a rapid shutdown system, for compliance with 2017 NEC 690.  

Features

Rapid Shutdown Initiator

Dimensions

Specifications

1

2

3

4

5

5

5

1  

R

APID

 S

HUTDOWN

 switch

Initiates the rapid shutdown function.  Turning to the 

S

OLAR

 O

FF

 

position removes the 24-volt signal 

enabling MLPE devices to operate.  This switch can 
be secured with a padlock. 

2

 

 S

OLAR

 O

N

 LED indicator

Green LED indicator.  It illuminates when DC voltage 
is present and the 

R

APID

 S

HUTDOWN

 switch is in the 

S

OLAR

 O

N

 

position.

3

  

S

OLAR

 O

FF

 LED indicator

Red LED indicator.  

S

OLAR

 O

FF

 

must be illuminated to 

confirm PV shutdown.  The 

S

OLAR

 O

FF

 

indicator tells 

responders that the 

R

APID

 S

HUTDOWN

 switch is in the 

S

OLAR

 O

FF

 

position to create a “safe” condition.

4

  

A

FCI

 

LED indicator

Red LED indicator; illuminates when receiving an 
“arc fault” signal from an ICS Plus combiner.

NOTE

:  The red 

A

FCI

 

indicator is not functional unless used with the ICS Plus family 

of PV combiners.

5

  ½” Electrical knockouts

These accommodate conduit and a UL 514-compliant 

  (EKO) × 3

fitting for communication wires.

Application with FireRaptor MLPE 

This product will activate the rapid-shutdown circuit of the FM100 charge controller if connected to MLPE devices.  
It may optionally activate an inverter on/off circuit to de-energize the inverter.  This product is intended for 
installations requiring more than 40 IMO FireRaptor OBFRS-ESW1 units.  Up to 114 FireRaptor units may be 
used per RSI.  Up to six RSI units may be used on a single system.
When the RSI opens for a rapid shutdown event, it removes power from all FireRaptor devices.  The RSI 

A

UX

 R

SI

 

C

OMMAND

/S

TATUS

 O

UTPUT

 connection will place the FM100 controller into a rapid shutdown state.  The controller’s 

rapid shutdown terminals may be connected to other FM100 controllers for a “daisy-chained” rapid shutdown 
configuration, or may be connected to the inverter’s on/off circuit.  See the opposite side of this sheet for instructions.

Other Applications 

Similar applications are also possible with other MLPE products such as the TIGO TS4-A-S and TS4-A-F.

12.0" 

(30.5 cm)

14.75" 

(37.5 cm)

7.3” (18.5 cm)

6.6” (17.8 cm)

5.0” (12.7 cm)

14.1" 

(35.8 cm)

3.75” (9.5 cm)

All ½”

Voltage

Power Draw

Ambient Temperature

LED Indicators

Knockouts

DC Input

Enclosure Rating

24 Vdc ± 3%

0.06 Adc

–25 to 60°C

S

OLAR

 O

N

 

S

OLAR

 OFF 

A

FCI

½”

24 Vdc ± 3%

UL Type 3R

900-00268-01-001 REV A

©2020 OutBack Power.  All Rights Reserved.