background image

DESCRIPTION  & USE

INTRODUCTION

The Life IQ

TM

range of chargers is designed to recharge

24 V, 36 V, 48 V or 80 V batteries, depending on the version 
supplied, from a single phase or 3-phase mains supply. 
The micro processor-controlled unit automatically recognises
the battery (voltage, capacity, charge level, etc.) and very 
effectively analyses its condition for optimum handling.
Several charging profiles are available (vented lead/acid
batteries, VRLA batteries (Hawker XFC

TM

), gel batteries or

Water Less

®

batteries) depending on the configuration 

selected by the user. The capability for desulphation, 
equalisation and refresh charging is also included.

EXTERNAL COMPONENTS

Presented below:

Single phase model                        3 phases model

Ref.

Function

1.

Ventilation louvres.

2.

Display and control panel

3.

AC input cable.

4.

Battery cable.

5.

Wall mounting frame.

6.

Case retaining screw.

7.

Navigation button – Stop/Start button of the charger 

8.

USB 

9.

Option connector (Electro-valve, BSI, Ethernet…).

Figure 1: 

Principal components of the charger.

CONTROL PANEL

Incorporates the Display and the Control Panel. See
Chapters “The Menus” and ”Using the charger” to get
more detailed information.

LCD Display

The display is fitted with 5 different colours indicating the
status of the charger: 

Functions of keys

The keys offer the following general functions:

Key

Function

Navigation in the menu. 
Start/End of list (Press 2 seconds)   

The central button is equipped with 
a two-coloured LED Green/Red 
(Green: charger is waiting, Red charger 
operating)

GREEN/RED

Stop or Start of charge

Selection of active menu or validation 
of value stored

Cancel the value stored 
(Press 2 seconds) 

Start an equalisation charge.
Access to a sub-menu.

Access to the menus (press 3 seconds)
Close the window.

UNPACKING

The charger is delivered with the following:

2 m AC mains cable.

3 m DC battery cable.

This technical manual.

MECHANICAL INSTALLATION

The charger must be mounted in a vertical position. For
wall mounted chargers, the bottom of the charger must be
at least 0.60 m from the floor and/or the charger below 
and the top of the unit at least 1.0 m from the ceiling. The
minimum distance between two adjacent chargers must 
be 0.30 m. 

See paragraph 

Recommendations and avoid areas where

the chargers may be splashed with water, or saline 
environments.

The charger is held by 4 x M6 or M10 screws suitable for
the type of support. The drilling pattern is depending on 
the charger model. Refer to technical data.

ELECTRICAL CONNECTIONS

Single phase and 3-phase input

Connection to the mains supply will be 230V AC single
phase or 400V AC 3-phase and must be connected using 
a suitable plug and adequately sized circuit breaker (not
included). Current requirements in Amps are indicated on
the charger information plate.

Battery output

It is essential to ensure correct polarity. However, reversed
polarity will result in blowing the output fuse, inability to
charge and the fault code 

DF2

to be displayed. 

See Fault

Codes.

Connection to the battery should be done using the cables
supplied:

RED cable: battery POSITIVE.

BLACK cable: battery NEGATIVE.

FACTORY SETUP

The charger is delivered with a factory setup as follows:

Profile: As 

ordered

Output DC cable length: 

3 m

Configuration: As 

ordered

Automatic equalisation: 

No

Delayed start enabled:

No

001

FUNCTION

Waiting status until battery connected

Battery on charge

Alternating, on charge indicating a defect
pump or overdischarge or thermal fault

Battery charged

Charger faults DF1, DF2, DF3, TH

Alternating, battery charged with defect
pump or overdischarge 

COLOUR

Dark blue

Light blue

Light blue  Orange

Green

Red

Green        Orange

002