9
If the pump and/or cutter is being used for the first time,
be certain to bleed air from the hydraulic system as
described in Section 8.4 before using the cutter.
Verify that pump oil level is correct and that there are no
oil leaks or other obvious problems.
Figure 2, Hydraulic and Electrical Connections at Cutter
2
1
Connected View
Key:
1. Hydraulic Hoses and Couplers
2. Electrical Connectors and Cable
6.4 Pump Setup
Prepare the pump for operation as described in the
pump instruction sheet.
Before connecting the pump to the cutter, verify that the
pump relief valve is set at 10,150 psi [700 bar].
Figure 3, Hydraulic and Electrical Connections at Pump
To P
ump
2
1
1
Key:
1. Hydraulic Hoses and Couplers
2. Electrical Connectors and Cable
Summary of Contents for EWCH180