Enerpac EDI62 Series Instruction Manual Download Page 4

Instruction Manual for MODEL EDI62S

Instruction Manual for MODEL EDI62S

4/12

9/12

* I can set it by validating a linearize function by 
condition data.

Change the parameter selected.

Operation procedure diagram (Operation only with front switch)

Enter

Select a parameter to change.

Change the parameter selected.

Select a parameter to change.

Change the parameter selected.

Select a parameter to change.

Set low layer values of the condition data.

Set low layer values of the scaling data.

Set low layer values of the comparator data.

Setting low layer values of the linearized data.

Pattern selection

Mode

Shift data is reflected upon the measurement 
data on the Main Monitor.

Change the parameter selected.

Select a parameter to change.

Memory mode

Mode Push and hold

Push and hold

Push and hold

Keep on pushing the button for automatic increments.

When you push the Mode key, modes will change in the order of the 
maximum value, minimum value, (maximum value-minimum value) 
and input value. If you push and hold the Mode key when you are in 
the memory mode, all the values in memory will be cleared.

Mode

Mode

Mode

Mode

Mode

Mode

Mode

Mode

Mode

Mode

Digit selection

Value change

Mode

5.7 Linearization Data Setting Examples

* Linearization data setting function
Linearization data can be used as a function to set 2, 4, 8, or 16 linearity correction points.
Input data are displayed when the linearization function is OFF. The value to be displayed in response to the input data is output data. For each linearity
correction point, input and output data must be set.

For example, when the linearization function is OFF, and you wish to change the displayed value on the meter from 0 - 1000 to 0 - 1200, set N01.I
(Correction Point 1 Input Data) and N01.O (Correction Point 1 Output Data) to 0, N02.I (Correction Point 2 Input Data) to 1000, and N02.O (Correction Point
2 Output Data) to 1200.

In this case, the line between Correction Points 1 and 2 behaves according to the linearity correction setting. When the value of the input data exceeds
that at Correction Point 2, the behavior of the output data is no longer affected by the setting (the value of the output data changes from 1200 to 1001).
When more than two correction points are set, the behavior of a line connecting two sequential correction points is different from that of the next two
in sequence.

* Conditions for setting linearization data
To set linearization data, the value of the input data at one correction point must be larger than that at the previous one.

N01.I < N02.I < N03.I < N04.I ??< N15.I < N16.I

How to calibrate the zero input (ZRIN) value and the span input (SPIN) value using an actual load or the equivalent input

Push the center of Jog 1 to choose the digit you want 
to change, and move it up or down to change the 
value. In the left figure, pushing the jog1 while the 
least significant digit of 

1.000

 is selected, causes 

the lower digits to also be displayed.

Push and hold the Shift key, then the current 
measured value will be read as the setting.

Equivalent input calibration

Actual load calibration

Push and hold

1 or

Mode

1

1

1

Caution

* Comparator judgment values can be set not only from Jog 2 and Jog 3 but also from the low layers of the comparator data.

1

1 Press multiple times

1

1

1

1

1

1

1

Select a digit to change

Increase a value

Decrease a value

Mode

Change the selected digit

Save and return to measurement

Enter

Return to measurement

Operation Method

Measurement operation

* Not displayed unless the value of the protect level parameter of the condition data is PL0.

* Not displayed unless the linearization parameter of the condition data is enabled.

Correction Point 1 Output Data Setting (setting method is the same as above)

Correction Point 2 Input Data Setting (setting method is the same as above)

Correction Point 1 Input Data Setting

Correction Point 2 Output Data Setting (setting method is the same as above)

Correction Point 16 Output Data Setting (setting method is the same as above)

1

* Not displayed when the value of the linearization parameter of the condition data is smaller than 16.

Reviews: