Enerpac EBH35 Instruction Sheet Download Page 4

4

PPE Alert:

 Wear personal 

protective equipment 

(PPE) when using or 

servicing equipment.

Instruction Manual Alert:

 Read the 

instruction manual before using or servicing 

equipment.

1.5  Disconnecting Pump AC Power

  WARNING

Pump MUST be disconnected from the 

AC power supply before performing cutter 

maintenance, repair or cleaning procedures, or 

before allowing persons to reach inside the cutting 

head for any reason. Failure to observe this 

precaution may result in serious personal injury.

•  Cutter will operate immediately when pump motor 

is running, and either of the cutter push buttons is 

depressed.

•  If it is not possible to unplug the pump power cord 

from the AC power outlet, turn off and lock out 

power at the AC power supply and disconnect the 

hydraulic hoses.

•  Refer to the separate pump instruction sheet 

(provided with the pump) for detailed pump safety, 

operation and maintenance instructions.

1.6  Crush Hazard

  

DANGER

Cutter will start immediately when 

pump motor is ON and cutter advance or retract 

button is depressed.
DO NOT place hands, fingers or other parts of 

your body inside the cutting head unless pump 

is disconnected from AC power supply. Death or 

serious personal injury will result if cutter is operated 

while persons are working inside the cutting head.

•  Never reach into the cutting head while cutter is in 

operation.

•  Before reaching inside the cutting head for any 

reason, always stop the pump, relieve hydraulic 

pressure, and disconnect pump from AC power 

supply. 

CRUSH HAZARD
Do not reach inside cutting head 

unless pump is disconnected from AC 

power supply.

Summary of Contents for EBH35

Page 1: ...CAUTION and NOTICE NOTICE DANGER Indicates a hazardous situation that if not avoided will result in death or serious personal injury NOTICE WARNING Indicates a hazardous situation that if not avoided...

Page 2: ...es when they become dull Suitably maintained cutting tools with sharp edges are less likely to jam and are easier to control Always perform a visual inspection of the cutter before placing it into ope...

Page 3: ...r during operation Stay clear of cutting area Wear eye and face protection 1 3 General Hydraulic Tool Safety Precautions Tools with external hydraulic pumps NOTICE WARNING Failure to observe and compl...

Page 4: ...lock out power at the AC power supply and disconnect the hydraulic hoses Refer to the separate pump instruction sheet provided with the pump for detailed pump safety operation and maintenance instruc...

Page 5: ...ve Cutter may stall during operation if one or more of the maximum limits is exceeded 2 2 Specifications Cutter Model No Max Cutting Force Weight Max Hyd Operating Pressure Ambient Operating Temp Hyd...

Page 6: ...IONAL AND INTERNATIONAL STANDARDS Enerpac declares that this product has been tested and conforms to applicable standards and is compatible with all CE requirements A copy of an EU Declaration of Conf...

Page 7: ...must be rated at 10 150 psi 700 bar or above 6 2 1 Connecting the Hydraulic Couplers 1 Be sure that pump motor is stopped 2 Be certain there is no residual pressure in the hydraulic circuit If pressu...

Page 8: ...from AC power supply 2 Connect one end of the electrical cable to the electrical connector at the pump electrical control box 3 Connect the other end of the electrical cable to the electrical connecto...

Page 9: ...hown in Figure 5 Close the safety guard as shown in Figure 6 7 0 CUTTER SAFETY GUARD 7 1 Description When closed the safety guard prevents hand contact with the moving piston and blade See Figure 4 Th...

Page 10: ...the cutter use only the supplied lifting eyebolt See Figure 7 Use appropriately rated lifting equipment NOTICE WARNING Because the cutter components are very heavy there is a risk of cuts crushing or...

Page 11: ...ut when the item is positioned against the fixed blade of the cutter After adjusting the support bolt be sure that the support bolt retaining nut is snug tight against the support bolt mounting ear Th...

Page 12: ...tter model Refer to the chart in Section 2 1 of this manual 1 Figure 11 Operation Advance Cut 2 2 Be sure that the piston is in the home fully retracted position See Figure 8 3 Open the safety guard R...

Page 13: ...mp instruction sheet for pressure relief procedure The pump must be disconnected from the AC power supply The cutter must be given time to cool to prevent burns Procedures must be performed in a suita...

Page 14: ...Disconnect pump from AC power supply 9 5 Blade Replacement The use of worn blades decreases the effectiveness of the cutter and can also side load the cylinder possibly damaging the tool Pump overheat...

Page 15: ...fasteners are tight Replace repair or tighten components as needed NOTICE WARNING Always disconnect pump from AC power supply before beginning cutter blade replacement procedures Failure to observe th...

Page 16: ...ubleshoot and repair pump and solenoid control valve as required Service Center Cutter seal wear and or internal damage Repair cutter as required Service Center 2 Cutter vibrates during operation Loos...

Page 17: ...Notes...

Page 18: ...Notes...

Page 19: ...Notes...

Page 20: ...WWW ENERPAC COM...

Reviews: