background image

21

WS DS AS PS

13

12

11

10

9

8

7

HPS

6

21
22

23

24

FR

17

18

19

20

4

5

BK

R

BK

R

BK

BK

BK

BK

BK BK

R

BK

BL

BL

O

BL

W

R

BL

BL

O P

W

12~ 0 ~12

HP

SPR

1

LP

SP

R

2

FL

O

JA

N

D

Y

PU

M

P

AC F1 F2 F3

COM

P

FUSE 

RE

V

M

P

FACTORY STANDARD

FIELD INSTALLED

LINE VOLTAGE

LOW VOLTAGE

FACTORY STANDARD

FACTORY OPTION

WIRING INFORMATION

BK BLACK

BR

BL

BROWN

BLUE

G GREEN

GY GRAY

O ORANGE

P

PINK

PR PURPLE

R

RED

T

TAN

W WHITE

Y

YELLOW

WIRE COLOR CODE

TRANSFORMER WIRED FOR 240V,

BLACK & ORANGE WIRE FOR 240V,

BLACK & RED WWIRE FOR 208V

1.

NOTES:

LPS

CAPACTIOR

TER. STRIP

      COIL           

[CONACTOR]

FR

FAN RELAY

LPS

HPS

LEGEND

LOW PRESURE SWITCH

HIGH PRESURE SWITCH

DWG NUMBER

REV

2

3

1

2 amp

R

R

BL

Y

1

8

3

4

5

3 PHASE MONITER

R

R

R

R

N

L3

L2

L1

240V 208V

TRANSFORMER

12V

12V

FAN

MOTOR

BK

PR

BR

GR

BK

M

COMPRESSOR

USE COPPER CONDUCTORS ONLY

TORQUE SCREWS : 40 LB - IN

USE 75 ° C  600 V WIRE

WFS

COMPRESSOR 

CONTACTOR

1.

WATER FLOW SWITCH

SENSOR

REVERSING

SOLENOID

M

RS

WFS

O/

R

O/R

BL

BL

R

PO

W

E

R

 S

U

P

P

LY

20

8/230

 V 3 

Phas

e  60

H

z

040809

RAYPAK

USE TERMINALS 21 & 22 TO ATTACH 2  WIRE CONTROL SYSTEMS THAT HAVE THIER

OWN SENSORS FOR TEMPERATURE CONTROL.

SET POOL TEMPERATURE TO OFF AND SET SPA TEMPERATURE TO 104

2 WIRE REMOTE CONTROL

POOL HEAT PUMP,SCROLL COMPRESSOR

DIGITAL CONTROL, 208/230V 3 Phase

60Hz

REMOTE CONTROL

FIELD CONNECTIONS

T

C

S

P

0011099

Wiring Diagram — 208V/230V 3-Phase — Digital Models

Summary of Contents for 5310 Series

Page 1: ...0 Heat Pump Pool Spa Heater US C LISTED R NOTE The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components Installation and service personnel are required by some states to be licensed Persons not qualified shall not attempt to install service or maintain this ...

Page 2: ...2 ...

Page 3: ...to 300 150 to 200 200 to 400 Salt PPM 6000 MAXIMUM 6000 MAXIMUM 6000 MAXIMUM Free Chlorine PPM 2 to 3 2 to 3 2 to 3 Total Dissolved Solids PPM 3000 MAXIMUM 3000 MAXIMUM 3000 MAXIMUM Free Chlorine MUST NOT EXCEED 5 PPM Occasional chemical shock dosing of the pool or spa water should not damage the heater providing the water is balanced Automatic chemical dosing devices and salt chlorinators are usu...

Page 4: ...or Annual Check 12 Summer Shutdown 13 Freeze Protection 13 System Drain Down 13 Continuous Pump Operation 13 Maintenance 13 Air Coil Cleaning 13 Cabinet Care optional 13 Unplug Condensation Drain Holes 13 Troubleshooting 14 Service Call Verification 15 Power Supply 15 Water Flow 15 Time Clock Adjustment 15 Plumbing Diagrams 16 Wiring Diagram 208V 230V Single Phase Analog Models 18 Wiring Diagram 2...

Page 5: ...t safety information about hazards that may be potentially present in and around the heat pump pool heater CAUTION Elevated water temperature can be hazardous The U S Consumer Product Safety Commission has these guidelines 1 Spa water temperatures should never exceed 104 F 40 C A temperature of 100 F 38 C is considered safe for a healthy adult Special cau tion is suggested for young children 2 Dri...

Page 6: ...ch side of the unit at least 1 ft 30 cm from walls pipes and other obstructions Recirculation of cold discharge air back into the evaporator coil will greatly reduce the unit s heat ing capacity and efficiency This unit features an up flow discharge for quiet operation Air is pulled up through the evaporator coil and discharged through the top grill Allow at least 5 ft 1 5 m clearance above the un...

Page 7: ... latest edition and all applicable state and local codes Wiring diagrams are located on pages 18 and 19 Locate the equipment disconnect means within 3 feet of the heater s electrical enclosure or as close to the heater as possible Always satisfy applicable codes and standards In sizing power wiring be especially aware of up sizing requirements necessary due to wiring distances Always satisfy appli...

Page 8: ...8 5310 6310 8320 8320 38 1 2 ...

Page 9: ...ther case should be at least equal in size to the main pool spa circulation pip ing 4 In cold weather freeze zone areas shutoff valves ball or gate type must be installed at the unit inlet and outlet to facilitate service and cold weather drain down 5 Operate the pump and check the system for leaks Pressure Drop For system pressure drop information refer to Table B below CAUTION The heat pump pool...

Page 10: ...oximately 5 minutes Refrigerant Low Pressure Control Stops the com pressor if refrigerant suction low side pressure falls too low as a result of a malfunction loss of charge or extreme cold conditions Indicator Lamps There are 6 indicator lamps located on the unit control panel see Fig 3 below Power amber lamp When lit indicates power is applied to the unit Water Flow green lamp When lit indicates...

Page 11: ...ely 8 10 cooler than the air entering the unit If not see the Troubleshooting Section Controls Digital Models Your heat pump pool heater incorporates digital safety controls and indicators to ensure its safe reliable operation for models with analog controls see page 10 Water Pressure Switch Prevents operation when the pump is OFF The unit requires 5 psi minimum pres sure Digital Water Temperature...

Page 12: ...Board is displaying a temper ature and the pool pump is running and water is circulating properly 2 Verify that the Board is programmed so that the desired temperature of the Pool and Spa is higher than the displayed current water temperature 3 Allow the heat pump pool heater to operate for a few minutes to stabilize operating pressures and to allow various component temperatures to normal ize 4 V...

Page 13: ...he unit circuit breaker or disconnect switch to OFF 2 Leave the valves set the way they are unless addi tional circulation is required DO NOT stop all flow through the heat pump pool heater 3 IMPORTANT Remember to reset the valves before the next heating season or the unit will not operate properly Freeze Protection If the unit is installed in a location subject to freezing conditions it is import...

Page 14: ... gained during the day can be lost overnight Are rapid heat losses occurring in some other way such as high wind spillage rainfall flow through solar panels at night or a high water table B UNIT IS NOT RUNNING Is the temperature display or control panel Power lamp ON If not the circuit breaker may be shut OFF or tripped Reset the breaker by switching it OFF and then back ON Verify that the breaker...

Page 15: ... of Code OFF The desired programmed temperature point is lower than 60 F 15 C LP LP3 Shortage of refrigerant gas in the unit or faulty low pressure control The unit will show LP3 after 3 LP faults and shuts down the unit and pool pump for protection If this occurs you should call for service HP HP3 Low water flow in the unit or faulty high pressure control Check water flow backwash The unit will s...

Page 16: ... heat pump pool heater AFTER the filter and BEFORE any chlorinators Water In from pool or spa Water Out to pool or spa Filter Fig 7 For systems with pumps of 2 HP or greater over 80 gpm an external bypass is required Adjust the bypass valve to divert a minimum of 40 gpm through the heat pump pool heater Connections are 2 inch unions Plumb the heat pump pool heater AFTER the filter and BEFORE any c...

Page 17: ...17 UNITS UNITS UNITS Fig 8 Pool Piping for Heat Pump Pool Heater and Gas Pool Heater Fig 9 Pool Piping for Heat Pump Pool Heaters Multiple Primary Secondary ...

Page 18: ...PHASE 60 HZ A B C D 11 22 23 24 T S C P 2 amp FUSE 14 10 7 5 E D B TRANSFORMER 16 A C R M R T T SPA POOL 15 24 Volts AC HPS WPS 21 BK BK W BK BK BK BK O R BK W O W BK BK BK GY 6 T T BK BK BK P P BK W W W W BK GY GY R R BL R BL BK R W BK BK W W PR BK BR R BK BK 1 2 3 1 2 3 2 2 BL BK R R SWITCH SPA REMOTE POOL SHOWN IN POOL POSITION 3 240V 208V USE COPPER CONDUCTORS ONLY TORQUE SCREWS 40 LB IN USE 7...

Page 19: ...P SPR2 REVR FLO JANDY PUMP AC F1 F2 F3 COMP POOL HEAT PUMP SCROLL COMPRESSOR DIGITAL CONTROL PR 2 amp FUSE M 01 0669 072606 USE COPPER CONDUCTORS ONLY TORQUE SCREWS 40 LB IN USE 75 C 600 V WIRE POWER SUPPLY 208 230 V 1 PHASE 60 HZ TRANSFORMER WIRED FOR 240V BLACK ORANGE WIRE FOR 240V BLACK RED WWIRE FOR 208V 1 NOTES LEGEND LPS HPS COMPRESSOR CONTACTOR M CAPACTIOR TER STRIP COIL CONACTOR FAN POWER ...

Page 20: ...QUE SCREWS 40 LB IN USE 75 C 600 V WIRE 4 1 2 3 14 13 12 11 8 7 10 9 6 5 TO SLAVE 3 TO SLAVE 2 TO SLAVE 1 TO SLAVE 4 MASTER RELAY GY R R BL R BL BK R W 24 Volts AC ATTACH TO TERMINALS T C ON SLAVE UNITS POOL REMOTE SPA SWITCH TO REMOTE FACTORY STANDARD FIELD INSTALLED LINE VOLTAGE LOW VOLTAGE FACTORY STANDARD FACTORY OPTION WIRING INFORMATION USE TERMINALS 21 22 TO ATTACH 2 WIRE CONTROL SYSTEMS TH...

Page 21: ...S LEGEND LOW PRESURE SWITCH HIGH PRESURE SWITCH DWG NUMBER REV 2 3 1 2 amp R R BL Y 1 8 3 4 5 3 PHASE MONITER R R R R N L3 L2 L1 240V 208V TRANSFORMER 12V 12V FAN MOTOR BK PR BR GR BK M COMPRESSOR USE COPPER CONDUCTORS ONLY TORQUE SCREWS 40 LB IN USE 75 C 600 V WIRE WFS COMPRESSOR CONTACTOR 1 WATER FLOW SWITCH SENSOR REVERSING SOLENOID M RS WFS O R O R BL BL R POWER SUPPLY 208 230 V 3 Phase 60Hz 0...

Page 22: ...ons on the heat pump pool heater wiring block For a 3 wire control use the COMMON SPA and POOL connections on the heat pump pool heater wiring block Heater Settings 1 Make sure the heater is disabled on the remote control device Then push the SET key until POL is displayed Push the DOWN arrow key until OFF is displayed Wait until a temperature is displayed before beginning the next step 2 Push the...

Page 23: ...23 ...

Page 24: ......

Reviews: