background image

www.hi-velocity.com

•  Inoperative parts must be returned to Energy Saving Products Ltd. with an ESP RMA Form that 

includes model, serial number, and a detailed description of the entire problem. Inoperative 

parts must be returned in testable condition.

•  The warranty does not cover shipping costs to and from the factory, labour costs or any other 

cost associated with the installation of the replacement part.

•  Energy Saving Products Ltd. is not liable for any other damages, personal injury, or any other 

losses of any nature.

•  The liability of Energy Saving Products Ltd. is limited to and shall not exceed the cost of pre-

approved replacement parts.

Energy Saving Products Ltd. reserves the right to make changes to, improve upon, or discontinue its 

products at any time without public notice or obligation.  The descriptions and specifications contained in 

this document were in effect at printing.  Some illustrations may not be applicable to your unit. 

WARRANTY

three year limited warranty

 is extended on Electric Strip Heaters.

five year limited warranty

 is extended on all components in products manufactured exclusively by Energy 

Saving Products. These components include Motors, WEG Controller, Circuit Boards, Dampers, Zoning 

Controls, Blowers, Motor & Blower Assemblies, Heating Coils, Chilled Water Coils, and Air Conditioning 

Coils. 

Energy Saving Products Ltd. is proud to offer a limited warranty. This warranty applies strictly to the first 

purchaser at wholesale level and only to the fan coil unit and module. It does not include connections, 

attachments and other products or materials furnished by the installer.

Terms and Conditions

•  Any repair performed under warranty must be approved by Energy Saving Products Ltd. for this 

warranty to be valid.

•  This warranty replaces all other warranties expressed or implied. www.hi-velocity.com
•  Should there be multiple consecutive failures of a single part, warranty will not be considered 

until a contractor has contacted Energy Saving Products Ltd. Technical Department for assistance.  

Follow these steps for Service or Repair:

1. 

Contact the installer of the product or a licensed service company                                                                   

2. 

Contact the distributor      

 

 

 

 

 

                                        

3. 

Contact Energy Saving Products Ltd.  Mon-Fri  8 am – 4:30 pm MT  1-888-652-2219

This warranty excludes any damages caused by changes, relocation to, or installation in a new site. This 

warranty does not cover any defects caused by failure to follow the installation and operating instructions 

furnished with the fan coil. This warranty does not cover defects caused by failing to adhere to local 

building codes and following good industry standards. Failure to correctly install the fan coil, or material 

related to the unit, may result in improper system performance and/or damages and will void this warranty. 

This warranty does not cover products subjected to abnormal use, misuse, improper maintenance, or 

alteration of the product. Using the fan coil and/or module as a source of temporary heating/cooling 

during construction will void this warranty. 

Products sold by Energy Saving Products but manufactured by others, will carry the original manufacturer’s 

warranty. 

Summary of Contents for Hi-Velocity RCM-I Series

Page 1: ...nt Module Installation Manual Small Duct High Velocity Heating Cooling and Home Comfort Systems RCM I 70 2 5 3 Tons RCM I 100 3 5 5 Tons Includes Service Access Ports L Mounting Brackets Double Sided Mounting Tape Carry Over Screen For use with HVS 36 HVS 60 Variable Speed Heat Pumps ...

Page 2: ... is for use with HVS 36 and HVS 60 Inverter Heat Pump Condensing Units It does not come with thermal expansion valve as there are internal EXVs inside the Heat Pump When installing the RCM I Modules DO NOT INSTALL WITH TXVs The module will come with access ports that will need to be installed to read refrigerant pressures temperatures at the Evaporator RCM I Fig 01 shows approximate installation l...

Page 3: ...pipe every 5 feet or whatever local code states Run the pipes in the most direct route possible taking into account structural integrity building details and local building codes Minimum refrigerant pipe length is 16ft 6m If going less than 16 ft coil the additional copper pipe up in horizontal loops to ensure proper oil return If the evaporator is located above the condenser slope any horizontal ...

Page 4: ... out all refrigerant then weighing it back in based on the factory charge listed on the rating plate plus any additional refrigerant needed based on page 5 of Module HVS Variable Speed Heat Pump Manual Charging Wiring Outdoor Unit Make all connections to the outdoor unit with rain tight conduit and fittings Most building codes require a rain tight disconnect switch at the outdoor unit as well alwa...

Page 5: ...lar ducts A variance of 20 is allowable for sizing return ducts that connect to the RCM I or Hi Velocity Systems unit Where allowed by local codes a single return air grill may be used Note Return air grill must have equal minimum of free air area to return air Table 03 Return Air Duct Sizes Unit Rigid Ø Flex Ø Min Sq Inches Sq cm 50 51 52 12 305mm 14 356mm 120 774cm 70 71 12 305mm 14 356mm 120 77...

Page 6: ... Connection Sizes Liquid Line Lq 1 2 13mm 1 2 13mm Suction Line S 7 8 22 3mm 7 8 22 3mm Drain Connection 3 4 M CPVC 19mm 3 4 M CPVC 19mm Access Ports Yes Yes Freeze Stat Yes Yes Shipping Weight 34 lbs 15 4 kg 47 lbs 21 31 kg Module Size L x W x H 19 3 8 x 10 1 8 x 18 1 2 492mm x 257mm x 470mm 25 3 8 x 10 1 8 x 18 1 2 645mm x 257mm x 470mm RCM I Specifications Refrigerant Cooling Module 2 Smaller c...

Page 7: ...vel and only to the fan coil unit and module It does not include connections attachments and other products or materials furnished by the installer Terms and Conditions Any repair performed under warranty must be approved by Energy Saving Products Ltd for this warranty to be valid This warranty replaces all other warranties expressed or implied www hi velocity com Should there be multiple consecut...

Page 8: ... complete with an in house test lab Energy Saving Products prides itself on Customer Service and provides design services and contractor support For all of your Heating Cooling and Indoor Air Quality needs the Hi Velocity System is the right choice for you Phone 780 453 2093 Fax 780 453 1932 Toll Free 1 888 652 2219 www hi velocity com Hi Velocity HE Z Fan Coils Green Technology Build Smart Breath...