30
Generator
does not
produce
power (cont.)
Overload
indicator
light keeps
flashing
1.
Adjust choke lever according to instructions on
page 20
*When a connected device draws high startup power
the overload and output indicator light may briefly
illuminate, but this is to be expected. Once the device
starts up the overload indicator light will shut off and
the output light will remain green.
2.
Ensure device wattage consumption does not
exceed the generator’s maximum peak output.
No DC
output
1.
Disconnect battery, reset breaker and test the
battery for shorts.
2.
Clean battery connector nodes.
Generator
outputs
unstable
power
Connected
device does
not operate
consistently
Verify device start up requirements (Wattage
consumption). Do not exceed the generators maximum
peak output.
Device will
not start up
1.
Remove all loads, reset breaker, and check device
for defects. Do not exceed generator rating.
2.
Ensure device’s wattage consumption does not
exceed the generator’s maximum peak output.
Engine idle
unusually
high or low
Carburetor in need of tuning. For details on how to
adjust correctly please contact your local service
centre, or contact Midland Power Inc. at 1-877-528-
3772.
Generator
overheats
Operation is
normal when
generator
is cool,
overheating
occurs within
moments of
start up.
1.
Atmospheric temperature high (excess of 35°C).
2.
Insufficient air circulation in vicinity of generator.
3.
Low oil viscosity. Use oil according to oil usage
chart in user manual on page 26.
4.
Fouled spark plug, replace with equal or greater
quality plug.
Summary of Contents for EZV2200
Page 1: ...1 2600W GAS POWERED INVERTER GENERATOR 2000W GAS POWERED INVERTER GENERATOR...
Page 3: ...3 Let s get started You re excited to power up so we ll keep this brief...
Page 12: ...12...
Page 33: ...33 Chapter 8 Wiring Diagram...
Page 38: ...38...
Page 40: ...40...
Page 42: ...42 Enjoy Be sure to check energizergenerators com monthly for updates regarding your generator...
Page 43: ...43...
Page 44: ...44 TM...