4
5
3. Using the sheet metal screws (C) provided, drill
through the existing housing and secure the two
brackets (B) on each side with two screws each with
the tabs on each of the brackets (B) as shown.
3
4. Hang the retrofit assembly (A) onto the installed
bracket (B) by inserting the hinge pins into the
keyhole slots on each of the brackets (B). Slide the
hinge pins to the narrow end of the keyhole slots and
ensure that the retrofit assembly is secured before
releasing the retrofit assembly.
4
2. Slide the two brackets (B) on each side (2-ft ends) of
the existing fixture housing so that the flat base is
resting between the existing fixture edge and the drop
ceiling T-grid support lip.
www.energeticlighting.com
www.energeticlighting.com
A
D
C
B
INSTALLATION INSTRUCTIONS
2
Lock levers
side
Hinge
side
A
5. Hook the safety cables onto a hook or hole on the
fixture housing as a secondary safety support.
Connect the fixture wires to the supply wires -- black
to black, white to white, and green to green/bare.
WARNING:
If there is no ground supply wire, stop
installation and consult a qualified electrician.
NOTE:
If a 0-10v dimming system is available,
connect the purple and gray wires to the
corresponding purple and gray wires in the building
dimming system. If no dimming is required, leave the
wires unconnected.
INSTALLATION INSTRUCTIONS
5
Clean with a mild, non-abrasive glass cleaner and soft cloth. Do NOT use solvents or clean-
ers containing abrasive agents. When cleaning the fixture, make sure the power is turned
off, and any liquid spray should be applied to the cleaning cloth and not sprayed directly onto
the fixture itself.
MAINTENANCE AND CARE
Safety
cables
6. Swing the retrofit assembly (A) up into the fixture
housing until flush with the ceiling perimiter. Close
the two latches on each side and make sure that
retrofit assembly is fully secured at both ends before
completing installation.
6