11. Indicators
•
Indicator “Self-test” is on – hardware self test was passed
successfully
•
Indicator “Day/Night mode” is on – means a day time, if
day/night mode is enabled or if this mode is disabled
•
Main rocker switch is light up – means SIS-PWM is connected
to the power supply, there is power on all the sockets, the energy
consumed is being counted
•
“Wrong” indicator lights up, “OK” doesn’t light up - it means that
the wall socket is wrongly wired. It is recommended to fix the wiring
•
Indicators “OK” and “Wrong” light up together - it means that the
wall socket has problems with grounding. It is recommended to fix the
grounding of the wall socket