background image

3

EGM-PWM-LAN ENERGY METER WITH LAN INTERFACE

All brands and logos are registered trademarks of their respective owners

1.1. Features

LAN  Energy  Meter,  accessible  from  anywhere  within  your  LAN,  creates

insight in your energy consumption (voltage/current/power)

Get your power consumption curves via Internet - no permanent computer

connection required

No external IP-address at home? No problem. Your own user account on

EnerGenie.com will let you view and analyze the energy costs via Internet

with any PC or even mobile phone.

Power Meter software provides basic power consumption readings (home

use) and advanced readings (business/scientific use)

1.2. Specifications

Input: 220-240 V AC 50-60 Hz

Load max: 10 A

Power consumption max: 1.4 W

Computer  measurements:  voltage  and  current  measuring  (RMS  values),

true power measuring, real energy consumed during a time period (kWh)

Measurements range: up to 250 V AC, 10 A (RMS), 2500 W, 22 MW a year

Measurements accuracy: ± 2% (within 50 W –  2500 W power range)

Working conditions: (+10 to 40)

C, below 90% humidity

Resistance to short-circuits: 1.5 kV

Dimensions: 135 mm x 92 mm  x 78 mm

Net weight: 0.35 kg

Summary of Contents for EGM-PWM-LAN

Page 1: ...USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ КЕРІВНИЦТВО КОРИСТУВАЧА EGM PWM LAN ENERGY METER WITH LAN INTERFACE ...

Page 2: ...egistered trademarks of their respective owners Energy meter with LAN interface Energiemessgerät Energiemeter met LAN interface Compteur d énergie avec interface LAN Измеритель мощности и энергии с сетевым интерфейсом Вимірювач потужності та енергії з мережевим інтерфейсом ...

Page 3: ...e the energy costs via Internet with any PC or even mobile phone Power Meter software provides basic power consumption readings home use and advanced readings business scientific use 1 2 Specifications Input 220 240 V AC 50 60 Hz Load max 10 A Power consumption max 1 4 W Computer measurements voltage and current measuring RMS values true power measuring real energy consumed during a time period kW...

Page 4: ...re registered trademarks of their respective owners 1 3 System requirements LAN socket Internet connection is required for uploading the information to EnerGenie com server 1 4 Package contents EGM PWM LAN Software CD User manual LAN crossover patch cord LAN patch cord ...

Page 5: ...N INTERFACE All brands and logos are registered trademarks of their respective owners 2 Indicators and controls of the EGM PWМ LAN Figure 1 Day Night mode indicator Load indicator LAN socket Socket 1 Reset button LAN activity indicators ...

Page 6: ...trongly recommended to avoid damp or wet places for installation EGM PWM LAN should be connected to the European AC wall socket of the standard DIN 49 440 It is possible to connect the EGM PWM LAN to the power source via other multi plugs surge protectors voltage regulators or UPS 3 1 Preparing LAN configuration of EGM PWM LAN Before configuring EGM PWM LAN hardware settings please let it obtain i...

Page 7: ...connect EGM PWM LAN directly to the managing computer LAN adapter network card using the supplied crossover RJ 45 cable option B You might need to use this option if your LAN does not have DHCP server If you choose for option B then the following procedure is required to let EGM PWM LAN obtain a fixed IP address Power EGM PWM LAN on Press Reset button on the side control panel see Figure 2 above w...

Page 8: ...ers Gateway 192 168 0 1 DNS 0 0 0 0 DHCP enabled IP filtering disabled Power Manager client port 5000 EGM PWM LAN then searches for an IP address from your eventual DHCP server If no DHCP server is found within 1 minute EGM PWM LAN will then automatically revert to the default settings see above with IP 192 168 0 254 ...

Page 9: ...nected either to the same LAN where the device is if you chose option A section 3 1 or directly to the device with the crossover RJ 45 cable if you chose option B section 3 1 If for any reason the automatic setup does not work then open CD ROM drive in the My Computer window and launch SETUP EXE from the CD Follow instructions of the installation software NOTE Antivirus or firewall software may bl...

Page 10: ...ess the Search button NOTE only EGM PWM LAN within a local subnet can be found If your computer LAN adapter is not in the default subnet of EGM PWM LAN as might probably be the case if you chose option B section 3 1 you will have to change its IP address manually to be able to find EGM PWM LAN For example if you wish to find EGM PWM LAN with the default IP 192 168 0 254 the IP address of your comp...

Page 11: ...RFACE All brands and logos are registered trademarks of their respective owners Figure 4 The window of your default internet browser will be then opened to give you access to the built in web server See section 4 below for the further details ...

Page 12: ...xplorer or other browser and input the IP address of EGM PWM LAN for example http 192 168 1 241 If you have used LAN Find utility to locate EGM PWM LAN then you will be taken to this webpage automatically Login page will then be displayed see Figure 5 below NOTE Java script must be enabled in your Internet Explorer or another browser settings Otherwise you get an error message WARNING JAVASCRIPT I...

Page 13: ...ed Irms Vrms and Energy The EnerGenie page also allows you to setup access of your EGM PWM LAN from anywhere via Internet even if it does not have an external IP address To setup this free service you should follow two simple steps Register the device To restrict access to the device via the Internet to the rightful owner only the device should be registered e g assigned to your account To registe...

Page 14: ...n regardless whether you created a new or used an existing account your EGM PWM LAN is automatically registered Return back to the EnerGenie page of your EGM PWM LAN see Figure 6 below Push Activate button to let the device initiate communication with EnerGenie com server The EnerGenie page will then start updating itself until the Status becomes Registered Activated Connected see Figure 6 below ...

Page 15: ...of their respective owners Figure 6 After a successful registration and activation the button Register will be renamed to Login and will then open the Login page of EnerGenie com and the button Activate will turn into Deactivate If by any reason you would eventually decide to stop managing your ...

Page 16: ...registration of your EGM PWM LAN and assign it to another account it will be possible via EnerGenie com website see section 5 below See section 5 below for further details on managing your EGM PWM LAN via EnerGenie com website Below the page you can see the current time of the web server and eventual information about the last successful timer synchronization Automatic timer synchronization is use...

Page 17: ...respective owners 4 3 LAN settings page Figure 7 On the LAN settings page see Figure 7 above you can set up DHCP IP address Subnet mask Gateway DNS server and IP filter up to 3 IP addresses can then be enabled for remote access The new settings will be applied immediately after you press the Apply button ...

Page 18: ... It can be found on this page or on the bottom sticker of the device The MAC address is fixed and cannot be changed DNS server address is important to be properly set up in case you wish to enable the NTP timer correction option see section 4 4 below IP filter option is needed to prevent unauthorized access to the server It restricts the web server access from any computer with IP address differen...

Page 19: ...ir respective owners 4 4 Device settings page On the device settings page you can setup name password and internal time of EGM PWM LAN see Figure 8 below Figure 8 To be able to setup the schedule of EGM PWM LAN you have to first setup its internal clock correctly Enter the current local time and date ...

Page 20: ... to the Internet and have a proper DNS server setting see section 4 3 above Server name can be convenient to identify the web server if you have more than one EGM PWM LAN It is Server 1 by default The password is necessary to access EGM PWM LAN both from your web browser and the Power Manager software see section 6 below This password is case sensitive and can be up to 32 characters long Alphanume...

Reviews: