background image

3

EG-PMS2

PROGRAMMABLE USB SURGE PROTECTOR

All brands and logos are registered trademarks of their respective owners

1. Introduction

Congratulations  with  your  purchase  of  this

Energenie  Power

Manager

.  Your EG-PMS2  is  an  advanced  surge  protector  with  power

management features. Four sockets are individually manageable by the

computer via USB interface.

The sockets can be switched on/off by a timer schedule, by user or

different  events.  It  is  also  possible  to  pre-program  the  unit  event  timer

schedule  (hardware  schedule)  and  then  disconnect EG-PMS2  from the

managing computer. The device can be used as an advanced standby-

killer.

1.1. Features

The main rocker switch enables switching all the sockets on and off

In addition to it every manageable socket can be switched on and off

via the software control window

The unit can be pre-programmed via hardware-based schedule. The

hardware schedule will work even when the managing computer is

switched off

The  unit  will  keep  performing  the  programmed  hardware  time

schedule even  after EG-PMS2  is  disconnected  from  the power  for

some time

Summary of Contents for EG-PMS2

Page 1: ...USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF EG PMS2 PROGRAMMABLE USB SURGE PROTECTOR...

Page 2: ...pective owners PROGRAMMABLE SURGE PROTECTOR PROGRAMMIERBARE STECKDOSENLEISTE PROGRAMMEERBARE STEKKERDOOS PARASURTENSEUR PROGRAMMABLE Do not plug several sockets in line Do not use if covered De energi...

Page 3: ...also possible to pre program the unit event timer schedule hardware schedule and then disconnect EG PMS2 from the managing computer The device can be used as an advanced standby killer 1 1 Features Th...

Page 4: ...applications could be switch my scanner on when I want to scan or switch my printer off whenever I exit Windows 1 2 Specifications Input voltage max 250 VAC 50 60 Hz Maximum load current 10 A Maximum...

Page 5: ...Indoor use Dimensions 378 x 98 x 55 mm Net weight 1 kg 1 3 Hardware requirements Computer running Windows 2000 XP Vista 7 or Windows 8 is required for using the Power Manager software One free USB por...

Page 6: ...spective owners 2 Indicators and controls of EG PMS2 Figure 1 Main rocker switch Z with self restoring fuse Indicator Socket 3 Non manageable socket Indicator Socket 4 Indicator Socket 2 Indicator Soc...

Page 7: ...eans that this particular socket is switched on The indicator Surge Ok see Figure 1 above stays on if the surge protection is well functioning and non manageable sockets first and last are switched on...

Page 8: ...in this manual If EG PMS2 is switched on then the Surge OK indicator is lit In this case both non manageable sockets are now live and connected to the power supply The sockets Socket 1 Socket 2 Socket...

Page 9: ...ower of the devices connected to EG PMS2 exceeds 2200 Watts the circuit breaker may power EG PMS2 off In this case please remove the excessive load first and then after 2 3 minutes press the main rock...

Page 10: ...of their respective owners family After a successful installation a socket icon will appear in your system tray 4 1 Managing EG PMS2 Double click on the socket icon in the system tray or select Open...

Page 11: ...egistered trademarks of their respective owners Push the Device settings button bottom right here to set the device specific options see Figure 3 below Figure 3 Double click on the device and you will...

Page 12: ...GE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 4 Double click on each socket will switch it on or off green color means the socket is switched on red col...

Page 13: ...s are registered trademarks of their respective owners off Click the Settings button for each socket to access the Settings dialog box see Figure 5 below Figure 5 You can choose a different device and...

Page 14: ...an choose the icon from drop down list box Such icon is a fast way to switch the device connected to the socket on off or check the device status You can also assign a hot key to switch the socket on...

Page 15: ...registered trademarks of their respective owners 4 2 Setting up the hardware schedule Using the Hardware schedule button available from the Settings window you can create the hardware timer schedule...

Page 16: ...of their respective owners The window Add entry will appear see Figure 7 below In the dialog box specify the required time and the action Figure 7 To edit the record select it and click the Edit butt...

Page 17: ...ton see Figure 6 above You can select multiple entries using Ctrl and Shift keys You can also remove all entries from the schedule by clicking the Clear button see Figure 6 above To repeat your event...

Page 18: ...incorrect entries these will be highlighted and an error message will appear Click the Apply button again after correcting all the errors Use Sync button see Figure 6 above to synchronize device timer...

Page 19: ...The interval between the present and the last entry can not exceed 180 days Without loop the total execution period of the schedule can not exceed 215 days Loop period can not exceed 180 days NOTE If...

Page 20: ...e owners 4 3 Setting up the software schedule Using the Software schedule button available from the Settings window you can create the software timer schedule see Figure 10 below NOTE the software tim...

Reviews: