Metacentre VSD-R 4-20mA Box 

 

Page 11

 

 

4.0 Parts List 

 
 
 

VSD-R ‘mA’ Box 

 

Item Part No. 

Description

 

 
-  Y07ENER24.00 

Kit, VSD-R 4-20mA 

-     Y07ENER26.00     Unit, VSD-R 4-20mA 
-     Y07ENER14.00     Manual, User CD 
-     OVLY0502.00 

   Label, EnergAir 

1     Y07CMC5.00 

   Controller, S1 

2     Y05CM31.00 

   Unit, XPM-TAC24 

3     KPY05AC.01 

   PCB, Terminal VSD 

4     Y07CM49.00 

   Gland, Set - Pg13.5 

5     Y04CM59.00 

   Unit, i-PCB 

6     Y04CM29.00 

   Sensor, Pressure 

 

 

 

   0-16bar 

7     Y01ENER35.00     Module, Relay 24Vac 
8     Y01ENER20.00     Sensor, KTY Motor  
 

 

 

   Eye-Bolt; M16 

9     Y01ENER21.00     Sensor, KTY Motor  
 

 

 

   Eye-Bolt; M20 

10    Y01ENER22.00     Sensor, KTY Motor  
 

 

 

   Eye-Bolt; M24 

11    Y01ENER24.00     Sensor, KTY 
 

 

 

   Ring Tag; M4 

 

 
 
 
 
 
 
 
 

5.0 Technical Data 

 

VSD-R ‘mA’ Box 

 
Dimensions 

291mm x 241mm x 152mm 

Weight  

6.5kg (14lb) 

Mounting 

wall, 4 x screw fixings 

Enclosure 

IP54, NEMA 12 

Supply   

/- 10% 

  115Vac 

+/- 

10% 

Power  

50VA 

Temperature 

0°C to 46°C  (32°F to 115°F) 

Humidity 

95% RH non-condensing 

 

 

 

 

 
 
 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Mounting Dimensions 

24mm

238mm

24mm

188mm

8mm Ø

236mm

286mm

 

i-PCB

4

 

5

 

2

 

1

 

3

 

6

 

8

 

9

 

10

 

11

 

M4

M16

 

M20

 

M24

 

KTY

A2 A1

22 12

24 14

21 11

7

 

Summary of Contents for metacentre VSD-R

Page 1: ...MANY09117A GB VSD R 4 20mA Box User Manual bar TM VSD R 4 20mA...

Page 2: ...eration 3 1 User Interface 3 2 Display 3 3 Status Symbols 3 4 Indicators 3 5 Operation 3 6 User Display Menu Items 3 6 Compressor Not Responding 3 8 VSD R Box Status 3 9 VSD R Box Fault Codes 3 10 Com...

Page 3: ...uit and will open in the event of a drive fault The contact should close within 2 seconds at power up and remain closed when the drive is stopped unless a fault condition occurs 1 2 Compressor Basic R...

Page 4: ...ontactor s will energise prior to power being applied to the main motor and de energise after power is removed from the main motor This functionality will significantly prolong the service life of the...

Page 5: ...the fault code More than one active fault code item can exist at any one time Access Code Access to page list displays higher than page P00 is restricted by access code To access menu mode pages pres...

Page 6: ...Any value or option adjustment that has not been confirmed and entered into memory will be abandoned and the original setting maintained A flashing Key symbol displayed with any Item indicates the It...

Page 7: ...r Log 1 to 15 Error Log 15 2 2 Menu Item Settings 5 6 1 Operating Pressure Set Points Pu Unload pressure set point PL Load pressure set point PL VSD target pressure 5 6 2 Pressure Units Select Selects...

Page 8: ...Flashing system management unit off or RS485 communications disrupted local pressure control Compressor Running i PCB Waiting for compressor to Run Compressor Loaded i PCB Waiting for compressor to L...

Page 9: ...value will scroll through the available items C VSD R Box status SP Percent motor speed Tm Motor temperature T2 2 nd temperature optional Only shown if the optional 2nd temperature is activated After...

Page 10: ...AND Loaded True Loaded False Ready False Ready True AND Load Request True Load Request False Ready True No Fault VSD Panel Fault or VSD R Box Fault Initialisation Complete Waiting For Run Request 5 R...

Page 11: ...nd outputs 0836E PLL unlocked error Alarm 2050A Auxiliary Alarm input 3 9 Compressor Fault The VSD R Box is not designed to detect individual compressor faults view the compressor controller for compr...

Page 12: ...Y01ENER35 00 Module Relay 24Vac 8 Y01ENER20 00 Sensor KTY Motor Eye Bolt M16 9 Y01ENER21 00 Sensor KTY Motor Eye Bolt M20 10 Y01ENER22 00 Sensor KTY Motor Eye Bolt M24 11 Y01ENER24 00 Sensor KTY Ring...

Page 13: ...ial permissible between compressor discharge and pressure sensor if sensor fitted at location B 5 If air isolation valve fitted and sensor fitted at location B ensure compressor has independent excess...

Page 14: ...Sensor Motor KTY Temperature R5 R6 Di6 Contactor Feedback VSD Drive Stop Run Drive Fault Ai2 Ai1 Di7 4 20mA Speed Control notused VSD Drive Fault Fan Contactor option Delta Contactor option Line Conta...

Page 15: ...C Di4 C Di5 A GND Ao Ai3 4 20mA Pressure Sensor Motor KTY Temperature R5 R6 Di6 Contactor Feedback VSD Drive Stop Run Drive Fault Ai2 Ai1 Di7 4 20mA Speed Control Aux Trip VSD Drive Fault Fan Contact...

Page 16: ...erature R5 R5 R6 R6 Di6 R1 R2 R3 R4 R5 R6 L2 C 1 2 3 4 5 6 7 8 L1 Ao X05 X06 X03 X04 RS485 1 C035 J 1 X02 X01 Ai3 A GND Ai2 Ai1 VDC A GND L2 L1 RS485 2 XPM TAC24 S1 Controller 24Vac 1 2 1 2 2 1 X03 X0...

Page 17: ...N N L E BLUE BROWN RED GREEN VIOLET WHITE ORANGE BLACK FH1 FH2 FH3 FH4 FH5 1 VOLTAGE SELECT 2 3 4 X04 2 1 2 X03 X02 X01 T3 15A T1 6A T1 6A T1 0A T1 0A 1 2 3 4 115V 10 230V 10 1 2 3 4 IEC 5x20mm Modul...

Reviews: