![Enerdrive MagnaSine ME AGS Operator'S Manual Download Page 17](http://html1.mh-extra.com/html/enerdrive/magnasine-me-ags/magnasine-me-ags_operators-manual_2409562017.webp)
©2010 Enerdrive Pty Ltd
17
6. Troubleshooting
To test the system for proper operation, hold the AGS Switch in the “TEST” position
and release. The generator should start and run for 30 seconds and then shut off.
If the generator does not start and stop as expected, refer to the troubleshooting
chart below. If the problem persists, contact your dealer.
LED INDICATION
SYMPTOM
OPERATION/
SOLUTION
RED
= GEN FAULT
Gen won’t start.
Check Gen start
wiring, Turn “off” then
“enable” to reset.
RED
= GEN FAULT
Gen won’t stay on.
Check Gen B+ wiring,
check gen, turn “off”
then “enable” to reset.
GREEN BLINK
= GEN START
Gen start initiated
No problem
GREEN SOLID
= GEN START
Gen started ok.
No problem
READY OFF
= POWER OFF
No 12 or 24 volt DC
power to control box.
Check fuse, check
12 or 24 volt DC
wiring, Turn “off” then
“enable” to reset.
READY BLINK
= NO REMOTE
No remote control
sensed or plugged in.
Check remote
connections, Turn
“off” then “enable” to
reset.
READY SOLID
=POWER ON
Normal operation
No problem