This program is used if the temperature sensor fails. By selecting Program B, the temperature sensor is
ignored allowing for operation of the system until you can replace the faulty temperature sensor.
Running this program will get you into “Limp-Home Mode” but you will have no temperature control on
the system thus leaving the lithium protection system compromised. Contact Enerdrive to arrange for a
replacement Temperature Sensor.
PROGRAM B:
The Enerdrive Advanced BMS Relay Driver will turn the main battery relay OFF every 6 minutes if the SOC%
on the battery monitor is still below the set point. So this may need to be reset a few times before the SOC%
set point reaches its re-engagement point.