Page 8
Fuse or Circuit Breaker:
•
DC-rated fuse or DC-rated circuit breaker connected along the DC positive line is required.
•
Select a fuse or circuit breaker with 60A/16V minimum rating for the 12V DC Input Inverter(s).
•
Based on the size of the battery bank chosen, determine the overall short circuit current rating of
the battery bank from the battery manufacturer. The fuse or circuit breaker chosen has to be able
to withstand the short circuit current that may be generated by the battery bank.
DC Input Cable:
•
Use of low resistance wire is required for all the DC connections between the inverter and the
battery bank.
•
Use minimum 16mm2 cable with a maximum length of 1.5m for 12VDC inverter.
Inverter Installation:
•
Choose an appropriate mounting location.
•
For indoor use only, the orientation of the unit can be mounted in any direction except with the DC
Input panel facing downwards.
•
For RV installation, the unit has to be mounted horizontally.
•
Use mounting template on the following page to mark the positions of the mounting screws.
•
Drill the 4 mounting holes and place the inverter in position and fasten the inverter to the mounting
surface.
Enerdrive Inverter Gen2 400W 12V Owners Manual Rev: 1.4
More information https://www.caravansplus.com.au