Lithium Battery Type
Parameters below are required for setting:
• Charging Voltage (13.9V, 14.0V, 14.1V, 14.2V, 14.3V, 14.4V)
• Maximum Charging Current (see table below)
• Termination Charging Current (current to define when the charging
process will terminate)
The following table shows the available charging voltage, maximum
charging current, and the available termination charging current.
Model
Charging Voltage
Maximum Charging
Current
Termination
Charging Current
EN31220
13.9V to 14.4V in 0.1V increments
* 20A
* 1A / 2A / 4A
System Supply Mode = 13.5VDC
15A
0.75A / 1.5A / 3A
Bulk Restart = 13.3VDC
10A
0.5A / 1A / 2A
5A
0.3A / 0.5A / 1A
EN31240
13.9V to 14.4V in 0.1V increments
* 40A
* 2A / 4A / 8A
System Supply Mode = 13.5VDC
20A
1A / 2A / 4A
Bulk Restart = 13.3VDC
10A
0.5A / 1A / 2A
5A
0.3A / 0.5A / 1A
EN31260
13.9V to 14.4V in 0.1V increments
* 60A
* 3A / 6A / 12A
System Supply Mode = 13.5VDC
40A
2A / 4A / 8A
Bulk Restart = 13.3VDC
20A
1A / 2A / 4A
5A
0.3A / 0.5A / 1A
EN32430
27.8V to 28.8V in 0.1V increments
* 30A
* 1.5A / 3A / 6A
System Supply Mode = 27.0VDC
20A
1A / 2A / 4A
Bulk Restart = 26.6VDC
10A
0.5A / 1A / 2A
5A
0.15A / 0.25A / 0.5A