Battery Charger Voltage
Battery Type
Absorption
Float
Equalisation
GEL
14.4 V
13.7 V
N.A.
AGM
14.7 V
13.6 V
N.A.
Flooded
14.4 V
13.3 V
15.5 V (See Note1)
Lithium
Constant 14.2 V, 14.3 V, 14.4 V (See Note2)
N.A
Program (Power Supply)
Constant 13.3 V, 13.5 V, 13.7 V (See Note3)
N.A
*
For 24V model charger multiply above voltages by 2.
** For Concorde™ branded batteries (lifeline, sun xtender) use flooded setting and consult battery
supplier for equalisation recommendations
Note 1: Equalisation setting can only be used on flooded battery type selection only. See
more details on Procedure to Equalise the Flooded Battery.
Note 2: Charger will terminate charging when charging current drop to below the set charger
termination value.
Note 3: Charger is acting as a power supply with selected constant output voltage and preset
maximum output current. With this setting, only Bank 1 can be used, Bank 2 and 3 is disabled.
Battery Bank Size Recommendation
The battery charging current rating is based on the battery size. Each
battery bank should meet the minimum Ah rating as shown. If a smaller
size battery bank is used, set the current rating to lower value to match
with the battery bank size. Normally, the minimum battery bank capacity
is based on twice the charger current rating.
EN31220
EN31240
EN31260
EN32430
Current
Setting
Battery
Capacity
Current
Setting
Battery
Capacity
Current
Setting
Battery
Capacity
Current
Setting
Battery
Capacity
5A
Min 10Ah
5A
Min 10Ah
5A
Min 10Ah
5A
Min 10Ah
10A
Min 20Ah
10A
Min 20Ah
20A
Min 40Ah
10A
Min 20Ah
15A
Min 30Ah
20A
Min 40Ah
40A
Min 80Ah
20A
Min 30Ah
20A
Min 40Ah
40A
Min 80Ah
60A
Min 120Ah
30A
Min 60Ah