4.1.2
BATTERY TYPE “USE” SETTINGS
Step 1:
Enter the “USE” battery type. For detailed operations of entering the “USE” battery type refer to
the below instructions.The battery parameters that can be local set are shown in the
table below:
SYS
(System Voltage)
BCU
(BULK)
FCU
(FLOAT)
LVA
(LOW VOLTAGE
ALARM)
LVD
(LOW VOLTAGE
DISCONNECT)
LEN
(cut charging
below ≤0°C)
NO
YES/NO
12VDC
14.4V
13.8V
12.6V
11.1V
9~17V
9~17V
9~17V
9~17V
12/24V
1)
Under the “USE” battery type, press the
“SYS” interface.
button to enter the
2)
Press the
3)
Press the
button to modify the voltage 12/24V.
button again to display the current “SYS” value.
4)
Press the
button to confirm and enter the next parameter.
6)
Press the
increase
by 0.1V, long press to decrease by 0.1V).
button to modify the parameter (short press to
5)
Press the
button again to display the current voltage value.
7)
Press the
button to confirm and enter the next parameter.
Parameters
Default Range
Settings on EN43510, EN43520, EN43530 & EN43540
Press the
button to modify the switch status.
Note: Controller will exit automatically from the current interface after no
interaction for more than 10 seconds.