Summary of Contents for HeatStar HSBF10NG

Page 1: ...r gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air...

Page 2: ...resh air at once Have heater serviced Some people are more affected by carbon monoxide than oth ers These include pregnant women persons with heart or lung disease or anemia those under the influence...

Page 3: ...COMBUSTION AND VENTILATION WARNING This heater shall not be installed in a confined space or unusually tight construction un less provisions are provided for adequate combus tion and ventilation air...

Page 4: ...r gas appliances Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors Example Gas water heater 40 000 Btu hr Vent Free Heater 20 000 B...

Page 5: ...y or drafty areas WARNING Heater must be mounted to maintain the minimum clearances shown in Figure 4 If pos sible provide greater clearances from the floor ceil ing and joining walls Figure 3 Ventila...

Page 6: ...ll be located Make sure mounting bracket is level For wall stud mounting locate one end of the mounting bracket over a wall stud WARNING Maintain minimum clearances shown in figure 7 If you can provid...

Page 7: ...installing bottom mounting screw into wall stud drill holes at marked locations using 9 64 drill bit 5 Re place heater onto mounting bracket 6 Place spacers between bottom mounting holes and wall anch...

Page 8: ...net Ground Joint Union Equipment Shutoff Valve From Gas Meter 4 W C to 10 5 W C Pressure Tee Joint 1 8 NPT Plug Tap Cap Pipe Nipple Tee Joint 3 8 NPT Pipe Nipple Sediment Trap Test Gauge Connection Re...

Page 9: ...floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call you gas supplier from a neigh bor s phone...

Page 10: ...0 seconds This will allow air to bleed from the gas system 6 Push in control knob and rotate control knob back to OFF position then rotate counterclock wise to PILOT IGN position This will light pilot...

Page 11: ...ng control knob Control knob must be locked at the desired position TO TURN OFF GAS TO APPLIANCE SHUTTING OFF HEATER 1 Turn control knob clockwise to the OFF posi tion 2 Turn off all electrical power...

Page 12: ...l let you determine your own comfort levels The LED temperature indicator measures approximate room temperature around the heater Note The LED temperature indicator DOES NOT oper ate with or control t...

Page 13: ...you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 psig This can be done by using a vacuum cleaner i...

Page 14: ...l valve damaged 1 Burner orifice is clogged 2 Burner orifice diameter to small 3 Inlet gas pressure is too low 1 Manifold pressure is too low 2 Burner orifice is clogged When ignitor button is pressed...

Page 15: ...leaks see Checking Gas Connections page 8 1 This is common with most heaters If noise is excessive contact qualified service person 1 Refer to Fresh Air for Combustion and Ventilation page 3 through...

Page 16: ...36 915cm Sides 6 152cm 10 5 267cm 10 5 267cm Floor min to top of carpet 2 51cm 2 51cm 2 51cm Fabric flammable objects 36 915cm 36 915cm 36 915cm BF6NG BF10NG BF20NGT BF30NGT BTU Available 6 000 10 000...

Page 17: ...39 38 35 16 21 16 1 16 2 6 26 29 34 24 22 3 19 13 23 18 10 3 11 1 2 1 4 22 2 33 1 22 1 25 9 5 1 3 1 1 27 1 28 1 IR20NGT IR30NGT BF20NGT BF30NGT 4 15 14 42 9 7 26 22 3 22 1 33 1 1 4 44 42 45 3 Thermos...

Page 18: ...8 70640 70640 70640 70640 Thermostat Valve assembly 1 9 70641 70641 70641 70641 Ignitor Module Mounting Bracket 1 10 70642 70643 Back Plate 1 11 70644 70644 70644 70644 Ignitor Module Battery powered...

Page 19: ...70679 70679 70679 Strain Relief Grommet 1 70689 70692 Right Burner Gas Tube 1 70690 70693 Right Middle Gas Burner Tube 1 70598 Left Middle Gas Burner Tube 1 70691 70694 Left Burner Gas Tube 1 70695 70...

Page 20: ...1 22 1 70396 70396 70396 Heat Shield Top 1 22 3 70330 70331 70331 Heat Shield Back 1 23 70663 70663 70663 Regulator Mounting Bracket 1 24 70665 70665 70665 Floor mount feet 2 26 70332 70332 70332 Gril...

Page 21: ...ted Natural Gas Fired Room Heater NON Thermostat models IR10NG BF6NG BF10NG 16 2 16 1 16 21 40 38 36 35 29 1 43 22 1 1 2 1 3 23 2 24 5 10 13 3 26 8 22 3 6 44 7 1 4 1 1 42 22 1 1 1 26 7 8 23 24 13 1 4...

Page 22: ...e of gas used Natural Gas Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealer of this product If they can t supply orig...

Page 23: ...23 Installation Instructions and Owner s Manual Unvented Natural Gas Fired Room Heater Notes...

Page 24: ...arts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such...