13
Version 1.7
English
Optional Electric Solenoid Kit
1)
If you ordered your sprayer with the
optional electric solenoid controls, mount
contoller in cab; make sure this is mount-
ed where it will not obstruct operators
view.
2)
Connect the wire harness from the
controller to the 3 electric valve banks
on sprayer by plugging in the matching
ends to the valves.
3)
Connect white pressure line from con-
troller to valve bank with provided con-
nectors. Make sure white pressure hose
is bottomed out all the way into connec-
tor fittings before tightening connector.
4)
This unit comes with power wires that
you will either need to add gator clips
to or wire directly to a power source. If
gator clips are used, connect to battery;
red to positive and black to negative.
GETTING STARTED