Endura DAS5200 Series Installation Manuallines Download Page 3

C2670M

C

  

 

Page

 

3

 

INTRODUCTION

 

PURPOSE

 

OF

 

THIS

 

DOCUMENT

 

This

 

document

 

is

 

to

 

provide

 

Endura®

certified

 

integrators

 

with

 

a

 

guideline

 

of

 

installation

 

requirements

 

for

 

the

 

Endura

 

IP

 

Video

 

Management

 

System

 

components.

   

The

 

Endura

 

system

 

is

 

built

 

upon

 

industry

 

standard

 

technologies

 

and

 

utilizes

 

Information

 

Technology

 

(IT)

 

grade

 

components.

  

As

 

such,

 

all

 

best

 

practices

 

for

 

IT

 

equipment

 

site

 

planning

 

and

 

deployment

 

apply

 

to

 

Endura.

   

Given

 

the

 

constant

 

database

 

and

 

file

 

management

 

activity

 

that

 

is

 

natural

 

with

 

an

 

IP

 

video

 

management

 

system,

 

care

 

must

 

be

 

taken

 

to

 

avoid

 

sudden

 

shutdown

 

of

 

any

 

of

 

the

 

components.

  

As

 

power

 

fluctuations

 

and

 

disruptions

 

are

 

a

 

common

 

source

 

for

 

un

intentional

 

equipment

 

reboots,

 

conditioned

 

power

 

should

 

be

 

used

 

for

 

all

 

servers.

  

As

 

hard

 

disk

 

drive

 

reliability

 

is

 

negatively

 

impacted

 

by

 

temperature

 

extremes,

 

care

 

must

 

be

 

taken

 

to

 

ensure

 

that

 

hard

 

disk

 

drives

 

are

 

never

 

exposed

 

to

 

elevated

 

operating

 

temperatures.

  

If

 

either

 

conditioned

 

power

 

or

 

the

 

environmental

 

conditions

 

of

 

the

 

server

 

room

 

are

 

outside

 

the

 

specified

 

limits,

 

data

 

corruption

 

and

 

equipment

 

failure

 

can

 

occur.

 

The

 

Endura

 

system

 

should

 

only

 

be

 

turned

 

on

 

after

 

the

 

power

 

and

 

environmental

 

conditioning

 

systems

 

are

 

fully

 

tested

 

and

 

operational.

 

WARNING:

 

Do

 

not

 

turn

 

on

 

any

 

Endura

 

equipment

 

until

 

all

 

of

 

the

 

items

 

suggested

 

in

 

this

 

document

 

have

 

been

 

considered.

 

Without

 

adequate

 

power

 

and

 

ventilation

 

the

 

Endura

 

equipment

 

can

 

suffer

 

permanent

 

damage.

   

Should

 

you

 

encounter

 

any

 

questions

 

about

 

the

 

topics

 

covered

 

in

 

this

 

document,

 

please

 

contact

 

the

 

Pelco

 

Endura

 

Hotline

 

at

 

1

800

289

9100

 

(USA

 

and

 

Canada)

 

or

 

+1

559

292

1981

 

(international),

 

e

mail

 

[email protected]

.

 

 

 

Summary of Contents for DAS5200 Series

Page 1: ...IP Video Surveillance System Installation Guidelines for Endura Equipment C2670M C 9 09...

Page 2: ...POWER QUALITY 5 GROUNDING 7 ELECTROSTATIC DISCHARGE PREVENTION 8 ENVIRONMENTAL GUILDELINES 9 ENVIRONMENTAL ELEMENTS 9 OPERATING TEMPERATURE 10 HEATING VENTILATION and AIR CONDITIONING HVAC 12 NETWORKI...

Page 3: ...be used for all servers As hard disk drive reliability is negatively impacted by temperature extremes care must be taken to ensure that hard disk drives are never exposed to elevated operating temper...

Page 4: ...r Endura equipment Consult applicable regulations and standards for determining the proper wire gauge to use Generally you should install circuit breakers that are rated at 125 percent of the expected...

Page 5: ...tage or overvoltage for up to a few nanoseconds Under voltage brownout Low line voltages for an extended period of time NOTE If these issues are suspected or known to occur for a given site ensure tha...

Page 6: ...alculate the UPS size required for an installation with two NSM5200s connected to the same UPS Example Two NSM5200s are to be connected to the same UPS From Table A each NSM5200 dissipates 262 W of po...

Page 7: ...in each rack Any reading above 1 V measured between grounds should be considered a problem and investigated Grounding Guidelines Main building electrical ground The main electrical service entrance eq...

Page 8: ...500 V 14 800 V Source B A Unger Electrostatic Discharge Failures of Semiconductor Devices Bell Laboratories 1981 For the same relative humidity level a high rate of airflow produces higher static char...

Page 9: ...ees working in the room SITE CLEANLINESS It is critical that the installation site be completely clean and devoid of dust and debris created during the construction process Operation of the equipment...

Page 10: ...ne an extensive amount of design and engineering to keep the operating temperature of internal components as close to the ambient temperature of the room as possible As such maintaining the right ambi...

Page 11: ...rflow 274 Video Encoder NET5308T EXP 50 to 95 F 10 to 35 C Front to rear airflow 137 Video Encoder ENC5308 50 to 95 F 10 to 35 C Front to rear airflow 137 Video Encoder ENC5316 50 to 95 F 10 to 35 C F...

Page 12: ...ool air in through the front of the unit and exhaust heated air out of the back of the unit The ideal server room configuration utilizes cold and hot aisles HVAC vents placed either in the floor or th...

Page 13: ...t Endura Design Certification and collaborates with select switch vendors If additional assistance is required Pelco offers professional services for the Endura certified integrator CABLING All networ...

Page 14: ...e system manager is built upon a standard server platform it will suffer drift over time To maintain an accurate time for the entire system Pelco recommends pointing the Endura system to either the NT...

Page 15: ...ailable 100 percent of the time and the environmental conditions of the equipment location must be maintained within specification WARNING If either conditioned power or the environmental conditions o...

Page 16: ...n factors that may be helpful in determining those factors required for site planning Refrigeration 1 W 0 86 kcal h 1 W 3 412 BTU H 1 W 2 843 x 10 4 tons 1 ton 200 BTU minute 1 ton 12 000 BTU H 1 ton...

Page 17: ...party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequenti...

Page 18: ...Pelco Inc Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com...

Reviews: