12
Function and mode of operation
The power generator makes use of inverter technology.
The generator generates a higher frequency voltage that is
then recti
fi
ed and electronically turned into an AC voltage of
230V/50Hz by the inverter.
This measure makes it possible to generate an output voltage
with a constant frequency and voltage regardless of the engine
speed.
In ECOtronic mode, it is possible to specify a load-dependent
engine speed. The RPM varies between approx. 3500-4600 min
-1
in this case.
The ECOtronic system can be deactivated for consumers with
high switch-on currents (pumps, cut-off grinders, compressors,
etc.). The engine speed is then approx. 5000 min
-1
.
Function and mode of operation