Accuracy
Reference
conditions
Calibration temperature at 25 °C
Linearity
≤
0.15%
Load influence
≤
0.1%
Ambient
temperature
influence
≤
0.1%
in range
0 °C...50 °C
≤
0.2%/10 K
in range
-20 °C... 0 °C
Application conditions
Installation conditions
Installation angle
No limitation
Installation hints
Vibration free installation point, protection from external heating
Ambient conditions
Ambient
temperature
-20...+50 °C
Storage
temperature
-20...+70 °C
Climatic class
To EN 60 654-1 Class B2
Ingress
protection
IP 20
Electromagnetic
compatibility
(EMC)
Immunity to EN 61 326, Class A (industrial environment)
Mechanical construction
Model/
dimensions
Housing for top hat Din rail to EN 50 022-35
Dimensions in mm
Acctive barrier
23