background image

RIA45

Operation

Hauser

13

Are the mounted cables strain-relieved?

-

Are the power supply and signal cables correctly connected?

See the wiring diagram on the
housing.

6  

Operation

Thanks to the device's simple operating concept, it is possible to commission the device for

many applications without a printed set of Operating Instructions.
The FieldCare operating software is a quick and convenient way of configuring the device. It

contains brief explanatory (help) texts that provide additional information on individual

parameters.

6.1  

Operating elements

6.1.1  

Local operation at the device

The device is operated by means of the three keys integrated in the front part of the device

• Open the Configuration menu
• Confirm an entry
• Select a parameter or submenu offered in the menu

Within the Configuration menu:
• Scroll step-by-step through the parameters/menu items/characters offered
• Change the value of the selected parameter (increase or decrease)
Outside the Configuration menu:
Display enabled and calculated channels, as well as min. and max. values for all the active channels.

You can always exit menu items / submenus by selecting "x Back" at the end of the menu.
Leave the setup directly without saving the changes by pressing the ‘-’ and ‘+’ keys

simultaneously for longer (> 3 s).

6.1.2  

Configuration via interface & PC configuration software

L

CAUTION

Undefined states and switching of outputs and relays while configuring with the

configuration software

Do not configure the device when the process is running.

To configure the device using the FieldCare Device Setup software, connect the device to your

PC. You need a special interface adapter for this purpose, e.g. the Commubox FXA291.

Summary of Contents for ria45

Page 1: ...a substitute for the Operating Instructions pertaining to the device Detailed information is provided in the Operating Instructions and other documentation Available for all device versions via Intern...

Page 2: ...RIA45 2 Endress Hauser Order code Ext ord cd Ser no www endress com deviceviewer Endress Hauser Operations App XXXXXXXXXXXX XXXXX XXXXXX XXX XXXX XX Serial number 1 3 2 A0023555...

Page 3: ...ounting procedure 8 4 4 Post installation check 9 5 Wiring 9 5 1 Electrical connection 9 5 2 Post connection check 12 6 Operation 13 6 1 Operating elements 13 6 2 Display and device status indicator L...

Page 4: ...ground prior to establishing any other connections The ground terminals are located on the interior and exterior of the device Interior ground terminal potential equalization is connected to the supp...

Page 5: ...process variables and displays them on its multicolored screen Processes can be monitored and controlled with the device s outputs and limit relays The device is equipped with a wide array of software...

Page 6: ...ompliance with the safety requirements and cannot be held responsible for the consequences that may result 4 Compare the scope of delivery to the contents of the order 5 Remove all the packaging mater...

Page 7: ...transport Direct sunlight Vibration Aggressive media 4 Mounting 4 1 Installation requirements NOTICE High temperatures reduce the life time of the display To avoid heat accumulation ensure the device...

Page 8: ...n 114 67 1 2 1 3 4 2 4 3 5 6 6 A0010404 1 Installation in a panel 1 Screw the threaded rods item 1 into the positions provided on the mounting frame item 2 Four opposing screw positions item 3 4 are a...

Page 9: ...ger Before commissioning the device make sure that the supply voltage matches the voltage specifications on the nameplate Provide suitable switch or circuit breaker in building installation This switc...

Page 10: ...12 R11 R13 R22 R21 R23 L N A0010228 2 Terminal assignment of device channel 2 and relays optional Note Illustrated contact position of the relays if the power supply fails We recommend you connect a s...

Page 11: ...x8 x7 x6 x5 A0010581 RTD resistor 3 wire RTD 3 W x2 x4 x8 x7 x6 x5 A0010582 RTD resistor 4 wire RTD 4 W x2 x4 x8 x7 x6 x5 A0010583 Thermocouple TC x8 x7 A0010409 U 1 V U 1V x8 x7 A0010410 U 1 V U 1V...

Page 12: ...20 10 50 60 Hz L N PE A0010418 Interfaces Interface for configuring with PC software A0010417 5 2 Post connection check Device condition and specifications Notes Are cables or the device damaged Visu...

Page 13: ...t a parameter or submenu offered in the menu Within the Configuration menu Scroll step by step through the parameters menu items characters offered Change the value of the selected parameter increase...

Page 14: ...rom a list or specific location and click Next 4 In the next window click Browse and select the directory where the driver for the TXU10 FXA291 adapter is saved The driver is installed 5 Click Finish...

Page 15: ...f access protection is active If access protection by means of a code should be extended to the software this function should be activated in the extended device setup For this select Menu Setup Exper...

Page 16: ...imum value indicator In the event of an error the device switches automatically between displaying the error and displaying the channel see the Device self diagnosis and Troubleshooting sections of th...

Page 17: ...etup Symbol for expert setup Symbol for diagnostics Accept entry If this symbol is selected the entry is applied at the position specified by the user and you quit editing mode Reject entry If this sy...

Page 18: ......

Page 19: ......

Page 20: ...www addresses endress com 71573626 71573626...

Reviews: