Prosonic S FDU90/91/91F/92/93/95/96
34
Hauser
Cantilever with mounting
frame or wall bracket
A0019589
A
Installation with cantilever and wall bracket
B
Installation with cantilever and mounting frame
1
Cantilever
2
Mounting frame
3
Wall bracket
Cantilever
The cantilever is used to mount the sensors FDU90, FDU91 and FDU92 above open channels for example.
A0019592
• The 35 mm (1.38 in) orifices are for the sensors FDU9x.
• The 22 mm (0.87 in) orifice may be used for an external temperature sensor (e.g. FMT131).
Fixing screws are supplied.
3
1
2
A
B
1
A
B
C
D
Material
Weight
Order code
585 (23)
250 (9.84)
2 (0.08)
200 (7.87)
galvanised steel
2.1 kg (4.63 lbs)
919790-0000
316Ti (1.4571)
2.0 kg (4.41 lbs)
919790-0001
1085 (42.7)
750 (29.5)
3 (0.12)
300 (11.8)
galvanised steel
4.5 kg (9.92 lbs)
919790-0002
316Ti (1.4571)
4.3 kg (9.48 lbs)
919790-0003
mm (in)
A
D
M
8
35 (1.4)
50
(2.0)
20
(0.8)
105 (4.1)
35
(1.4)
22
(0.9)
C
C
6.5
(0.3)
15
(0.6)
100 (3.9)
25
(1.0)
35 (1.4)
100 (3.9)
75 (2.9)
B
20 (0.8)
75 (2.9)
mm (in)