Proline Prowirl 72F, 72W, 73F, 73W
14
Hauser
Piping insulation
When insulating, please ensure that a sufficiently large area of the housing support is exposed.
The uncovered part serves as a radiator and protects the electronics from overheating (or undercooling).
The maximum insulation height permitted is illustrated in the diagrams. These apply equally to both the
compact version and the sensor in the remote version.
A0001868
1 = Flanged version
2 = Wafer version
Wafer version mounting set
The centering rings supplied are used to mount and center the wafer-style devices. A mounting set consisting
of tie rods, seals, nuts and washers can be ordered separately.
A0001888
Mounting wafer version
1 = Nut
2 = Washer
3 = Tie rod
4 = Centering ring (is supplied with the device)
5 = Seal
1
2
Esc
E
-
+
Esc
E
-
+
1
2
3
4
5