Proline Promass O 300
Hauser
21
Intrinsically safe values
Order code for
"Output; input 1"
Output type
Intrinsically safe values
"Output; input 1"
26 (+)
27 (–)
Option
CA
Current output
4 to 20 mA HART Ex i
U
i
= 30 V
l
i
= 100 mA
P
i
= 1.25 W
L
i
= 0
C
i
= 0
Option
HA
PROFIBUS PA Ex i
Ex ia
U
i
= 30 V
l
i
= 570 mA
P
i
= 8.5 W
L
i
= 10 µH
C
i
= 5 nF
Ex ic
U
i
= 32 V
l
i
= 570 mA
P
i
= 8.5 W
L
i
= 10 µH
C
i
= 5 nF
Option
TA
FOUNDATION Fieldbus
Ex i
Ex ia
U
i
= 30 V
l
i
= 570 mA
P
i
= 8.5 W
L
i
= 10 µH
C
i
= 5 nF
Ex ic
U
i
= 32 V
l
i
= 570 mA
P
i
= 8.5 W
L
i
= 10 µH
C
i
= 5 nF
1)
Only available for the Zone 1; Class I, Division 1 version
2)
Only available for the Zone 2; Class I, Division 2 version transmitter
Order code for
"Output; input 2";
"Output; input 3"
Output type
Intrinsically safe values or NIFW values
Output; input 2
Output; input 3
24 (+)
25 (–)
22 (+)
23 (–)
Option
C
Current output
4 to 20 mA Ex i
U
i
= 30 V
l
i
= 100 mA
P
i
= 1.25 W
L
i
= 0
C
i
= 0
Option
G
Pulse/frequency/switch
output Ex i
U
i
= 30 V
l
i
= 100 mA
P
i
= 1.25 W
L
i
= 0
C
i
= 0
Low flow cut off
The switch points for low flow cut off are user-selectable.
Galvanic isolation
The outputs are galvanically isolated from one another and from earth (PE).
Protocol-specific data
HART
Manufacturer ID
0x11
Device type ID
0x3B
HART protocol revision
7
Device description files
(DTM, DD
)
Information and files under:
HART load
Min. 250 Ω
System integration
Information on system integration: Operating Instructions → 92.
• Measured variables via HART protocol
• Burst Mode functionality
Summary of Contents for Proline Promass O 300
Page 95: ......