Proline Promass O 300
74
Hauser
Material
The housing material of the display and operating module DKX001 depends on the choice of
transmitter housing material.
Transmitter housing
Remote display and operating module
Order code for "Housing"
Material
Material
Option
A
"Aluminum, coated"
AlSi10Mg, coated
AlSi10Mg, coated
Option
L
"Cast, stainless"
Cast stainless steel,
1.4409 (CF3M) similar
to 316L
1.4409 (CF3M)
Cable entry
Corresponds to the choice of transmitter housing, order code for "Electrical connection".
Connecting cable
Dimensions
Remote operation
Via HART protocol
This communication interface is available in device versions with a HART output.
1
2
3
5
8
4
7
6
A0028747
37
Options for remote operation via HART protocol (active)
1
Control system (e.g. PLC)
2
Field Communicator 475
3
Computer with Web browser (e.g. Internet Explorer) for access to the integrated device Web server or
computer with an operating tool (e.g. FieldCare, DeviceCare, AMS Device Manager, SIMATIC PDM) with COM
DTM "CDI Communication TCP/IP"
4
Commubox FXA195 (USB)
5
Field Xpert SFX350 or SFX370
6
Field Xpert SMT70
7
VIATOR Bluetooth modem with connecting cable
8
Transmitter
Summary of Contents for Proline Promass O 300
Page 95: ......