Mounting
Micropilot M FMR245 with PROFIBUS PA
24
Hauser
Examples for the construction of stilling wells
L00-FMR245xx-17-00-00-en-006
100 %
0 %
Micropilot M
FMR 245
stilling well
with slots
full bore
ball valve
hole <1/10 pipe diameter,
single sided or drilled through
inside of
holes deburred
marker
e.g. welding neck flange
DIN 2633
< 1/10 Ø pipe
gap
1 mm
0.04”
£ £
150…500 mm
6”…20”
Diameter of o
of ball valve must always
be equivalent to pipe diameter.
Avoid edges and constrictions.
pening