Mounting
Micropilot M FMR 240 with Foundation Fieldbus
26
E Hauser
3.4.5
Installation FMR 240 with Wave Guide antenna
Optimum mounting position
L00-FMR240xx-17-00-00-de-003
Standard installation
For installations in a stilling well, follow the engineering hints on Page 14 and note the following
points:
• Can be mounted in a tank or bypass.
• No alignment is required.
• After mounting, the housing can be turned 350° in order to simplify access to the display and the
terminal compartment.
• Only suitable for media with low viscosity (
≤
500 cst), without the tendency for
build-up in the Wave Guide antenna.
• No minimum distance is required between the Wave Guide antenna and the tank bottom for
measuring-related purposes.
!
Note!
In the event of horizontal stress (e.g. agitators) , mechanical support is required or provide the Wave
Guide antenna with a protective pipe.