Technical data

Hauser

29

FML621A-CB

Multifunction, 2x U, I, TC ATEX

• 2x 0 to 20 mA or 4 to 20 mA per pulse

• 2x digital

• 2x SPST relay

FML621A-TA

Temperature (Pt100/Pt500/Pt1000)

Complete, including terminals and securing frame

FML621A-TB

Temperature, ATEX-approved (Pt100/PT500/PT1000)

Complete, including terminals

FML621A-UA

Universal - PFM or pulse or analog or transmitter power supply

Complete, including terminals and securing frame

FML621A-UB

Universal ATEX-approved - PFM or pulse or analog or transmitter power supply

Complete, including terminals

14.4   PROFINET® Interface

Order code RMS621A-P2

15  

Technical data 

15.1   Input

15.1.1   Measured variable

Density of liquids

15.1.2   Measuring range

Density range: 0.3 to 2 g/cm³

15.2   Output

15.2.1   Output and input variants

2-wire density (FEL60D) for density measurement

Connection to Density Computer FML621

15.2.2   Ex connection data

See safety instructions (XA): All data relating to explosion protection are provided in

separate Ex documentation and are available from the Downloads Area of the

Hauser-website. The Ex documentation is supplied as standard with all Ex

devices.

Summary of Contents for Liquiphant FTL62 Density

Page 1: ...Products Solutions Services Operating Instructions Liquiphant FTL62 Density Vibronic Density measurement for liquids BA02047F 00 EN 03 22 00 71578263 2022 06 30 Valid as of version 01 00 zz...

Page 2: ...Liquiphant FTL62 Density 2 Endress Hauser Order code Ext ord cd Ser no www endress com deviceviewer Endress Hauser Operations App XXXXXXXXXXXX XXXXX XXXXXX XXX XXXX XX Serial number 1 3 2 A0023555...

Page 3: ...16 5 3 Post mounting check 17 6 Electrical connection 18 6 1 Required tool 18 6 2 Connection requirements 18 6 2 1 Cover with securing screw 18 6 2 2 Connecting protective earth PE 18 6 3 Connecting t...

Page 4: ...vironment 30 15 3 1 Ambient temperature range 30 15 3 2 Storage temperature 30 15 3 3 Humidity 30 15 3 4 Operating altitude 30 15 3 5 Climate class 30 15 3 6 Degree of protection 30 15 3 7 Vibration r...

Page 5: ...erious or fatal injury CAUTION This symbol alerts you to a dangerous situation Failure to avoid this situation can result in minor or medium injury NOTICE This symbol contains information on procedure...

Page 6: ...e the device only for measuring the density of liquids Improper use can pose hazards Ensure that the device is free of defects while it is in operation Use the device only for media to which the wette...

Page 7: ...ary documentation that is an integral part of this manual 2 5 Product safety This device is designed in accordance with good engineering practice to meet state of the art safety requirements has been...

Page 8: ...k Coatings Plastic coated or enamel coated flange pipe extension and tuning fork No coating temperature spacer pressure tight feedthrough 4 Incoming acceptance and product identification 4 1 Incoming...

Page 9: ...r identification Order number extended order code serial number Technical data degree of protection Firmware version hardware version Approval related information reference to Safety Instructions XA D...

Page 10: ...ation from above for device with long pipe Minimum distance between the fork tip and the tank wall or pipe wall 10 mm 0 39 in 1 A0048473 3 Installation examples for a vessel tank or pipe 1 Vessel insu...

Page 11: ...dium flow Flow velocity 2 m 6 6 ft per second Prevents the formation of air bubbles 1 1 A0039718 4 Installation example in pipes in the medium flow Installing the tuning fork away from the direct flow...

Page 12: ...9 84 in The pressure and temperature sensor must be installed on the outlet side of the flow direction after the Liquiphant density sensor When installing pressure and temperature measuring points dow...

Page 13: ...in 1 0002 36 mm 1 42 in 1 0001 38 mm 1 50 in 1 0001 40 mm 1 57 in 1 0000 Installation in a bypass Correction factor r as a factor of the internal diameter of bypass D for entering in the Density Comp...

Page 14: ...D for entering in the Density Computer FML621 or ReadWin2000 D r D A0039707 44 mm 1 73 in 44 mm 1 73 in 1 0225 46 mm 1 81 in 1 0167 48 mm 1 89 in 1 0125 50 mm 1 97 in 1 0096 52 mm 2 05 in 1 0075 54 m...

Page 15: ...s if required 5 1 5 Take clearance into consideration Allow sufficient space outside the tank for mounting connecting and replacing the electronic insert A0048474 8 Take clearance into consideration 5...

Page 16: ...ily and buildup is avoided A0042207 10 Markings to align the tuning fork Installing in pipes Flow velocity up to 5 m s with a viscosity of 1 mPa s and density of 1 g cm3 SGU Check for correct function...

Page 17: ...urns 2 Turn the housing align the cable entry Avoid moisture in the housing provide a loop to allow moisture to drain off 3 Tighten the external locking screw 5 3 Post mounting check Is the device und...

Page 18: ...aking sure that the securing screw is positioned correctly There should not be any gap between the cover and housing 2 x 0 7 Nm 4 A0039520 13 Cover with securing screw 6 2 2 Connecting protective eart...

Page 19: ...Connection diagram Connecting the FEL60D electronic insert to the Density Computer FML621 A Connection wiring with terminals B Connection wiring with M12 plug in housing according to EN61131 2 standar...

Page 20: ...duct These parameters must be transmitted to the Density Computer FML621 This type of adjustment achieves an even higher level of accuracy Field adjustment With a field adjustment the density determin...

Page 21: ...er FML621 with display and operating unit 5 PLC The measurement can be affected by Air bubbles at the sensor Unit not fully covered by medium Solid media buildup on sensor High flow velocity in pipes...

Page 22: ...ainless steel 7 to 12 mm 0 28 to 0 47 in Pay attention to the following when using the M20 coupling Following cable entry Counter tighten the coupling Tighten the union nut of the coupling with 8 Nm 5...

Page 23: ...L60D 1 LED red for warning or alarm 2 LED yellow stability of measurement 3 LED green operational status device is on 4 Pulse output terminals 8 Commissioning 8 1 Function check Before commissioning t...

Page 24: ...1 Diagnostic information via light emitting diodes 10 1 1 LED at electronic insert indicator power supply or off No supply voltage present check supply voltage Reverse polarity check terminal assignm...

Page 25: ...r repair concept The devices have a modular design Customers can carry out repairs For more information on service and spare parts please contact your Endress Hauser sales representative 12 1 2 Repair...

Page 26: ...information http www endress com support return material Select the region 2 Return the device if repairs or a factory calibration are required or if the wrong device was ordered or delivered 12 4 Dis...

Page 27: ...cast Material plastic Order number 71438291 165 6 5 32 1 26 140 5 51 115 4 53 122 4 8 140 5 51 A0038280 19 Weather protection cover for single compartment housing made of aluminum or 316L cast Unit o...

Page 28: ...connecting to a PC or modem FML621A AA Remote display for panel mounting B 144 mm 5 67 in H 72 mm 2 83 in T 43 mm 1 69 in RMS621A P1 PROFIBUS interface 51004148 Adhesive label printed max 2 x 16 chara...

Page 29: ...rsal ATEX approved PFM or pulse or analog or transmitter power supply Complete including terminals 14 4 PROFINET Interface Order code RMS621A P2 15 Technical data 15 1 Input 15 1 1 Measured variable D...

Page 30: ...y Operation up to 100 Do not open in a condensing atmosphere 15 3 4 Operating altitude As per IEC 61010 1 Ed 3 Up to 2000 m 6600 ft above sea level Can be extended to 3000 m 9800 ft above sea level if...

Page 31: ...2 5 psi LWARNING The maximum pressure for the device depends on the lowest rated element with regard to pressure of the selected component This means that it is necessary to pay attention to the proce...

Page 32: ...acceptance 8 Inspection 8 M Mounting Mounting requirements 10 N Nameplate 9 O Operational safety 7 P Post connection check 22 Product description Product design 7 Product safety 7 Purpose of this doc...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...www addresses endress com 71578263 71578263...

Reviews: