Incoming acceptance and product identification

Levelflex FMP53 FOUNDATION Fieldbus

6

Hauser

Use only original spare parts and accessories from the manufacturer.

Hazardous area

To eliminate danger to persons or the installation when the device is used in the hazardous

area (e.g. explosion protection, pressure vessel safety):

Check the nameplate to verify whether the ordered device can be put to its intended use in

the hazardous area.

Observe the specifications in the separate supplementary documentation, which is an

integral part of this manual.

3.5  

Product safety

This measuring device is designed in accordance with good engineering practice to meet state-

of-the-art safety requirements, has been tested, and left the factory in a condition in which it

is safe to operate. It meets the general safety standards and legal requirements.

NOTICE

Loss of degree of protection by opening of the device in humid environments

If the device is opened in a humid environment, the degree of protection indicated on the

nameplate is no longer valid. This may also impair the safe operation of the device.

3.5.1  

CE mark

The measuring system meets the legal requirements of the applicable EU directives. These are

listed in the corresponding EU Declaration of Conformity together with the standards applied.
The manufacturer confirms successful testing of the device by affixing to it the CE mark.

3.5.2  

EAC conformity

The measuring system meets the legal requirements of the applicable EAC guidelines. These

are listed in the corresponding EAC Declaration of Conformity along with the standards

applied.
The manufacturer confirms successful testing of the device by affixing to it the EAC mark.

4  

Incoming acceptance and product identification

4.1  

Incoming acceptance

Check the following during incoming acceptance:

• Are the order codes on the delivery note and the product sticker identical?

• Are the goods undamaged?

• Do the nameplate data match the ordering information on the delivery note?

• If required (see nameplate): are the Safety Instructions (XA) provided?

If one of these conditions is not met, please contact your Hauser sales office.

Summary of Contents for Levelflex FMP53 FOUNDATION Fieldbus

Page 1: ...s they are not a substitute for the Operating Instructions pertaining to the device Detailed information about the device can be found in the Operating Instructions and the other documentation Availab...

Page 2: ...ord cd Ser no www endress com deviceviewer Endress Hauser Operations App XXXXXXXXXXXX XXXXX XXXXXX XXX XXXX XX Serial number 1 3 2 A0023555 2 About this document 2 1 Symbols 2 1 1 Safety symbols DANGE...

Page 3: ...ls that must be connected to ground prior to establishing any other connections The ground terminals are located on the inside and outside of the device Inner ground terminal protective earth is conne...

Page 4: ...uthorized by the plant owner operator Are familiar with federal national regulations Must have read and understood the instructions in the manual and supplementary documentation Follow instructions an...

Page 5: ...with surfaces In the event of high medium temperatures ensure protection against contact to prevent burns 3 3 Workplace safety When working on and with the device Wear the required personal protectiv...

Page 6: ...onment the degree of protection indicated on the nameplate is no longer valid This may also impair the safe operation of the device 3 5 1 CE mark The measuring system meets the legal requirements of t...

Page 7: ...f the information on the measuring device and on the scope of the technical documentation pertaining to the device is displayed 4 3 Storage and transport 4 3 1 Storage temperature Permitted storage te...

Page 8: ...ents when mounting Distance A between the vessel wall and rod probes For smooth metallic walls 50 mm 2 in For plastic walls 300 mm 12 in to metallic parts outside the vessel Distance B between rod pro...

Page 9: ...curing screw using an open ended wrench 2 Rotate the housing in the desired direction 3 Tighten the securing screw 1 5 Nm for plastic housing 2 5 Nm for aluminum or stainless steel housing 5 2 2 Turni...

Page 10: ...en the housing and main electronics module and plug the display module into the electronics compartment until it engages Closing the cover of the electronics compartment 1 2 2 5 Nm 3 mm A0021451 1 Scr...

Page 11: ...nd 4 without integrated overvoltage protection 3 Connection switch output open collector terminals 3 and 4 with integrated overvoltage protection 4 Connection PROFIBUS PA FOUNDATION Fieldbus terminals...

Page 12: ...ge E 2 wire FOUNDATION Fieldbus switch output G 2 wire PROFIBUS PA switch output Non hazardous Ex nA Ex nA ia Ex ic Ex ic ia Ex d ia XP Ex ta DIP CSA GP 9 to 32 V 3 Ex ia IS Ex ia Ex d ia IS XP 9 to 3...

Page 13: ...Connect the potential matching line to the outer ground terminal before applying the power supply Required tools accessories For devices with a cover lock Allen key AF3 Wire stripper When using strand...

Page 14: ...sing shielded cables Connect the cable shield to the ground terminal 6 2 3 Plug in spring force terminals The electrical connection of device versions without an integrated overvoltage protection is v...

Page 15: ...compartment 2 Turn the securing clamp 90 in the clockwise direction and using an Allen key 3 mm tighten the screw of the securing clamp on the connection compartment cover with 2 5 Nm 7 Operation opt...

Page 16: ...or symbol if an error is active 1 2 Measured value symbols 1 3 Measured value 1 4 Unit 2 Measured value display bar graph 1 value 2 1 Bar graph for measured value 1 2 2 Measured value 1 including unit...

Page 17: ...8 Display module 1 Operating keys Key assignment Key Navigate down in the picklist Edit the numerical values or characters within a function Key Navigate up in the picklist Edit the numerical values...

Page 18: ...rement should generally be completely configured Setup Mapping Mapping of interference echos Setup Advanced setup Contains additional submenus and parameters For more customized configuration of the m...

Page 19: ...l display appears Calling up the menu via the context menu 1 Open the context menu 2 Press to navigate to the desired menu 3 Press to confirm the selection The selected menu opens 8 Commissioning 8 1...

Page 20: ...0 Operation Setup Main menu 0104 1 Display language English Espa ol Fran ais Display language English Deutsch 0104 1 Espa ol Fran ais Display language English Deutsch 0104 1 Betrieb Setup Hauptmen Spr...

Page 21: ...t D Distance E Empty calibration zero point L Level F Full calibration span 1 Setup Device tag Enter device tag 2 Setup Distance unit Select the length unit 3 Setup Tank type Select tank type 4 Setup...

Page 22: ...easured level L for verification purposes 9 Setup Distance Displays the distance D between the reference point R and the level L for verification purposes 10 Setup Signal quality Displays the signal q...

Page 23: ......

Page 24: ...www addresses endress com 71565960 71565960...

Reviews: