![Endress+Hauser HART Micropilot S FMR532 Brief Operating Instructions Download Page 21](http://html1.mh-extra.com/html/endress-hauser/hart-micropilot-s-fmr532/hart-micropilot-s-fmr532_brief-operating-instructions_2408392021.webp)
Micropilot S FMR533 4 to 20 mA HART
Commissioning
Hauser
21
5.3
Overview Basic Setup
L00-FMR533xx-19-00-00-en-003
SD
F
L
D
BD
E
flange:
reference point of
measurement
E = empty calibr. (= zero)
settings in 005
settings in 006
D = distance (distance flange / product)
L
display in 0A5
in 0A6
F
= full calibr. (= span)
= level
display
SD = safety settings
BD = blocking dist.
settings in 015
settings in 059