Operation
EngyVolt RV15
18
Key
View No. Description
3-phase, 4-wire
View No. Description
3-phase, 3-wire
View No. Single-phase, 2-wire
A0016377
1
A L1 (current L1)
A L2 (current L2)
A L3 (current L3)
1
A L1 (current L1)
A L2 (current L2)
A L3 (current L3)
1
A L1 (current L1)
2
A neutral current
3
A L1 MAX
(Current L1, maximum value, time-
integrated, maximum indicator
function)
A L2 MAX
(Current L2, maximum value, time-
integrated, maximum indicator
function)
A L3 MAX
(Current L3, maximum value, time-
integrated, maximum indicator
function)
2
A L1 MAX
(Current L1, maximum value, time-
integrated, maximum indicator
function)
A L2 MAX
(Current L2, maximum value, time-
integrated, maximum indicator
function)
A L3 MAX
(Current L3, maximum value, time-
integrated, maximum indicator
function)
2
A L1 MAX
(Current L1, maximum value, time-
integrated, maximum indicator
function)
4
A neutral current MAX
(Maximum value, time-integrated,
maximum indicator function)
5
I %THD* L1
(%THD current L1)
I %THD* L2
(%THD current L2)
I %THD* L3
(%THD current L3)
3
I %THD* L1
(%THD current L1)
I %THD* L2
(%THD current L2)
I %THD* L3
(%THD current L3)
3
I %THD* L1
(%THD current L1)
A0016379
1
kW active power
kvar reactive power
kVA apparent power
1
kW active power
kvar reactive power
kVA apparent power
1
kW active power
kvar reactive power
kVA apparent power
2
kW MAX (active power, maximum
value, time-integrated, maximum
indicator function)
2
kW MAX (active power, maximum
value, time-integrated, maximum
indicator function)
2
kW MAX (active power, maximum
value, time-integrated, maximum
indicator function)
3
PF power factor (with symbol: coil =
inductive, capacitor = capacitance)
3
PF power factor (with symbol: coil =
inductive, capacitor = capacitance)
3
PF power factor (with symbol: coil =
inductive, capacitor = capacitance)
A0016378
1
kWh electrical energy (active
component)
1
kWh electrical energy (active
component)
1
kWh electrical energy (active
component)
2
kvarh electrical energy (reactive
component)
2
kvarh electrical energy (reactive
component)
2
kvarh electrical energy (reactive
component)
*) %THD = % Total Harmonic Distortion
5.4
Configuration mode
The abbreviation for the parameter is displayed in the top display row in the configuration mode.
The middle row displays the parameter value. The bottom row is used to confirm the set value of
the parameter.
To enter the configuration mode, press and hold the and keys simultaneously for 5 seconds.
The screen to enter the 4-digit password is displayed. No default password is set. A password can
be used to prevent unauthorized access to the device settings. Once the correct password has been
entered, the device is on the first level of the menu structure. If a password was not configured for
the device beforehand, the setup is called up by pressing the key four times.
The parameter to be configured is selected with the and keys. When the key is pressed,
the parameter is selected and the user enters the second level of the menu structure. Values can be
changed at this level, such as the values of the system configuration, for example. There is a third
level in the menu structure for some parameters, such as the parameters for communication. This
level is reached in the same way. Once the necessary settings have been made, press the key to
return to the first level in the menu structure.