background image

download latest firmware for
RUNNING ORDER:
http://airways.endorphin.es

ENDORPHIN.ES® – RUNNING ORDER

Module design by Andreas Zhukovsky

Collection Spring/Summer 2021

Endorphin.es are made in Barcelona, Spain 

Follow, like, post and tag us at instagram:

@endorphin.es

WARRANTY

RTFM – be so kind and read the manual. It will provide you with the information you need to fully indulge the module you justpurchased – for which we like to thank you.
Enjoy your sound experiences, dear sonic traveller. Beginning from the product's purchase date a 1-year warranty is guaranteed for each product in case of any manufacturing errors
or other functional deficiencies during runtime.
The warranty does not apply in case of:
• damage caused by misuse • mechanical damage arising from careless treatment (dropping, vigorous shaking, mishandling, etc.)
• damage caused by liquids or powders penetrating the device • heat damage caused by overexposure to sunlight or heating • electric damage caused by improper connecting
The warranty covers replacement or repair, as decided by us. Please contact us via email for a return authorization before sending anything. Shipping costs of sending a module back for
servicing is paid by the customer. Device complies with all EU regulations concerning RoHS lead-free manufacturing and WEEE disposal

Visit us:

http://endorphin.es

https://youtube.com/user/TheEndorphines

https://facebook.com/TheEndorphines

https://www.instagram.com/endorphin.es/

For technical requests: [email protected]

For general requests: [email protected]

FURTH BARCELONA, S.L.

VAT ID: ES B66836487

FIRMWARE UPDATE

Repeats I/II :

manual knobs 

with CV inputs.

Set amount of active

trigger repeats or 

Euclidean trigger fills 

LISTEN TO THE HEART BEAT CAREFULLY 

• 6 HP wide, 2-track trigger generator 
• Zero-jitter clock generation: less than 50 microseconds internal clock jitter
• 101-style 16

th

 note input mode (step/rest) with manual or CV controllable

   amount of trigger repeats after the active trigger step happens.
• Euclidean mode enabled for each track, set total length and  the number of fills 
   inside the Euclidean circle. Fill amount is also CV controllable.
• Individual reset inputs per track, reset for track 1 is normalled to reset of track 2
• Clock divider for incoming external clock allows to quickly obtain various
   musical divisions on the fly incl. triplets of course, but more importantly tuplet
   mode lets you stretch the desired amount of trigger repeats into a single bar.
• Dedicated mute buttons for each track
• 8 patterns of trigger sequences stored in the module and will be recalled on
   each power cycle. 

  Depth: 30 mm (with plugged in ribbon cable)
  Power requirements: +12V: 30 mA, -12V: 10 mA

red/brown pair of wires correspond 

to negative -12V power connector

connect to the 

power bus board

POWER CONNECTION

back side of the module

connect to the module

from the back side

-12V / red stripe

polarity marking

- If in live mode, the buttons 
  are individual Track I and II 
  MUTE buttons.
- If in step record mode,
  the buttons are used for
  adding steps and rests.
- If in Euclidean record mode,
  the buttons set the length
  of the Euclidean circle 
  (+1 step pressing STEP and
  +16 steps by pressing REST)

  Rate/divider knob:
- if no clock cable is inserted, then
  this knob sets the speed of the internal
  clock in BPM, from 30 to 300;
- if clock is inserted via cable, this knob
   sets the speed of dividers/tuplets for
   the repeats.

© Endorphin.es® 2011–2021 

When a CV cable is inserted, 
each Repeats knob acts as CV
attenuator; expected CV range: 0...+5V 

power OFF you modular system:

hold STEP while powering your system again:

you will see the illuminati LED

slowly blink 

BLUE

:

WAV

with simple mono or stereo cable connect
audio output from your computer headphones
output to REPEAT 1 CV IN input of the module

Press PLAY and wait 2+ minutes.

Illuminati LED will quickly blink 

BLUE

.

The modue will reboot automatically blinking 

FUCHSIA

 LED after new firmware is installed

Disable alarms and notifications during

the update process as they will most likely

interupt the update procedure, flight mode

on phones is recommended.

When Illuminati LED flashes 

RED

that means signal is too low or too high:

Just reset the firmware update process by

pressing 

REST 

once and regulating the signal level

with 

RATE 

knob: full CCW: 1x amplification,

full CW: 10x amplification).

Video update guide: 

https://youtu.be/WKt7FdRGRYI

External clock
input, 16

th

notes clock 
expected 

(PPQN24÷6)

(0...+5V or +10V,
0.65V threshold)

Reset/syncronization trigger inputs.
Each trigger applied resets a certain track’s
sequence to its first step.
‘Reset in I’ is normalled to ‘reset in II’, if no
cable is inserted into ‘reset in II’.

  Track selector switch:
- record a trigger sequence or set
  the Euclidean length by switching
  to the left (track I) or right (track II);
- playback live mode in the middle 

Output 

Output 

Output 

track I and II trigger outputs,
trigger output length: 10 msec
Output range: 0...+10V

LED indicator:

- blinking to BPM in blue in live mode;

- lights up red in step recording,

- fuchsia in euclidean recording

Clock output:

- internal clock out jack: 30...300 BPM in 16

th

 notes

(PPQN24÷6) when no external clock applied;

- external clock output in 16

th

  notes after divider;

Output range 0...+10V

 

Output 

Output 

Reviews: