Magical balancer
5
Usage of Magical Balancer
32
5-7
Function button settings
WARNING
Do not perform any operations other than setting the function buttons in "Parameter
Mode".
This may change the control parameters of the magical balancer and cause
operational errors.
The functions of the function buttons can be changed by changing the parameters as follows
・
Load variation tracking function
When the function button is pressed, the position of the suspended load is maintained even when the
load changes.
Press the button again to release the function. (Default setting)
・
Balance inhibit function
When pressed, this function shuts off the main valve and prohibits the balance mode.
Press the button again or operate the grip to release it.
Operation Procedures
LCD display screen
1
Press the [Mode] key until "Parameter Mode" appears.
2
Hold down the [Shift] key and press the [Set] key to enter the edit
screen.
3
Hold down the [Shift] key and press the [
△
] key ([▼] key while holding
down the [Shift] key) to move the cursor.
4
Press the [
△
] key ([▼] key) to change the parameter value.
Load variation tracking function
:
1100 0000 0000 0000
Balance inhibit function
:
1101 0000 0000 0000
5
Press the [Set] key to enter the confirmation screen for editing.
Press the [Set] key again to confirm the edit.
6
The Edit Complete screen will appear.
7
Press the [Mode] key.
8
Press the [Mode] key again to exit the edit screen.
Parameter Write?
Param-01 0x0001
Parameter Mode
Param-01 0x0001
1101000000000000
Param-01 0x0001
1100000000000000
Parameter Mode
Param-01 0x0001
1100000000000000
Parameter Write
Completed !
Param-01 0x0001
1101000000000000
cusor