Installation of Magical Balancer
26
4-6
Connection of the power cable
WARNING
To prevent electric shocks caused by earth leakage, a qualified technician should
perform grounding work according to the standards of the area where the system is
installed.
In addition to the grounding, install an earth leakage breaker on the electric circuit.
Do not connect the ground wire to the following.
Gas and hydraulic piping: Danger of explosion or catching fire.
Telephone line and lightning rod: Danger in case of lightning.
Water pipe partially made of plastic in the middle: Does not serve as
the ground.
1
Check the supply voltage and connect
the “AC1” and ”AC2” cable to the power supply.
The ”E” cable is for grounding.
2
Be sure to install a grounding and
ground-short circuit breaker.
4-7
Post-installation checks
4-7-1 Checking the winding up operation
1
Confirm that the air supply pressure is within the range of 0.4MPa to 0.7MPa .
2
Turn on the power supply and confirm that the operation of the grip controller and its operation are
correct.See "5.Usage".
4-7-2 Checking the working range
WARNING
Never use the magical balancer at maximum length.
1
Check that the anti-bounce device does not work and the stopper does not hit the body in normal
operation.
2
Confirm that the operation range does not reach the upper and lower limits.
3
Confirm that the stopper stops after the "up" and "down" operation.
4-7-3 Other checks
1
Perform "up" and "down" motions by lifting the slinging load.
When trolleys are used, the trolley also traverses the tracks.
2
When traversing, operate the trolley for the entire length.
Also check the condition of the rails and the length of the air hoses. Usage