SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
ET1411-NTC-230VAC
DIGITAL THERMOSTAT
ENDA
INDUSTRIAL ELECTRONICS
2
3
0
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
3
V
A
O
U
T
P
U
T
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
NTC
SENSOR
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
ET1411-NTC-12
DIGITAL THERMOSTAT
ENDA
INDUSTRIAL ELECTRONICS
O
U
T
P
U
T
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
NTC
SENSOR
1
2
V
A
C
/D
C
1
0
%
5
0
/6
0
H
z
3
V
A
±
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
ET1411-NTC-24
DIGITAL THERMOSTAT
ENDA
INDUSTRIAL ELECTRONICS
O
U
T
P
U
T
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
NTC
SENSOR
2
4
V
A
C
/D
C
1
0
%
5
0
/6
0
H
z
3
V
A
±
Technical Specifications
Thank you for choosing ENDA ET1411 temperature controller.
Please read this document carefully before using this product. The guarantee will be
invalidated if the device is damaged by not following instructions detailed in the
manual. The company shall not be responsible for any damage or losses however
caused, which may be experienced as a result of the installation or use of this product.
Connection Diagram
ENDA ET1411 is intended for installation in control panels. Make sure that the device is used
only for intended purpose. The electrical connections must be carried out by a qualified staff
and must be according to the relevant locally applicable regulations. During an installation, all of
the cables that are connected to the device must be free of electrical power. The device must be
protected against inadmissible humidity, vibrations, severe soiling and make sure that the
operation temperature is not exceeded. The cables should not be close to the power cables or
components.
1/2
SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TÜRKÝYE
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Panel cut-out
Dimensions
Note :
1) Panel thickness
should be maximum
7 mm.
2)
If there is no 60mm
free space at the back
side of the device, it
would be difficult to
remove it from the panel.
ET
1
411-E-06-R
71mm
2
9
m
m
Flush mounting
clamp
For removing mounting clamps:
Push the flush-mounting
clamp in
direction
1
as
shown
in the figure below. Then, pull
out the clamp in direction
2.
1
ENDA
ET
1
411 DIGITAL THERMOSTAT
Holding screw
0.4-0.5Nm.
Equipment is protected throughout
by DOUBLE INSULATION
* 35 x 77mm sized.
* On-Off control.
* Single contact output for selectable heating
or cooling control.
* Single NTC probe input.
* Offset value can be entered for
NTC
probe.
* In the case of probe failure, output state can be
selected on, off or periodical running.
* Upper and lower limits of the setpoint can be
adjusted.
* Temperature unit can be selected °C or °F.
* CE marked according to European Norms.
Order Code :
ET
1
411-NTC-
1
Supply Voltage
230VAC.......230V AC
24................24V AC/DC
12................12V AC/DC
7
8
SUPPLY:
NOTE:
184-253V AC
50/60Hz 3VA
Line
Neutral
230V AC
Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected
1) Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identification of the
relevant instrument and it should be easily
accessible by the operator.
Supply voltage
230V AC +10% -20%, 50/60Hz or 12/24V AC/DC ±10%, 50/60Hz.
Power consumption
Max. 3VA
2.5mm² screw-terminal connections.
(±1%-1sec)
4 digits, 12.5mm, 7 segment yellow LED
Wiring
Scale
Sensitivity/Accuracy
Time Accuracy
Indicator
EMC
Safety requirements
The device is designed to operate in controlled electromagnetic environment)
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)
CONTROL
Control type
Single-setpoint control
On-Off control
Control algorithm
Hysteresis
Adjustable between 0.1 ... 20.0°C.
OUTPUT
ELECTRICAL CHARACTERISTICS
OUTPUT
Relay: 250V AC, 8A (
), NO+NC;
1/2 HP 240V AC
Cos
F
= 0.4 (for inductive load)
for resistive load
Mechanical 30.000.000; Electrical 100.000 operation.
Life expectancy for relay
ENVIRONMENTAL CONDITIONS
Height
Max. 2000m
80 , up to
40
%
31°C decreasing linearly 50% at
°C
Ambient/storage temperature
Max. relative humidity
0 ... +50°C/-25 ... 70°C (with no icing)
-60.0 ... +150.0°C (-76.0 ... +302.0°F)
0.1°C /
±1°C
Rated pollution degree
According to EN 60529 Front panel : IP65
Rear panel : IP20
Do not use the device in locations subject to corrosive and flammable gasses.
HOUSING
Housing type
Suitable for flush-panel mounting.
Dimensions
5
1
W77xH3 xD7 mm
Weight
Approx. 205g (A
)
fter packing
Enclosure material
Self extinguishing plastics
While cleaning the device, solvents (thinner, benzine, acid etc.) or
corrosive materials
must not be used.
SET
SET
ET1411
ENDA
OUT
°F
°C
3
5
m
m
77mm
SET
SET
ET1411
ENDA
OUT
°F
°C
Flush mounting
clamp
Depth
Panel
2
71mm
5mm
Rubber
packing
SN
: X
XX
XX
XX
XX
1
2
3
4
5
6
7
8
9
10
11
12
ET
14
11
-N
TC
-2
30
VA
C
DIG
IT
AL
T
HE
RM
OS
TA
T
EN
DA
IN
DU
ST
RIA
L E
LE
CT
RO
NIC
S
2
3
0
V
A
C
+
1
0
%
-2
0
%
5
0
/6
0
H
z
3
V
A
O
U
T
P
U
T
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
N
TC
SE
NS
OR