background image

SET

 EI141

ENDA

P

ROGRAMMABLE INDICATOR

IN

P

U

T

+

 

G

N

D

1

2

3

4

5

6

7

8

9 10 11 12

EI14

1

-230VAC

PROGRAMMABLE INDICATOR

ENDA

 

INDUSTRIAL ELECTRONICS

2

3

0

V

 A

C

 +

1

0

%

 -

 2

0

%

5

0

/6

0

H

  

7

V

A

SN: XXXXXXXXX

8 680407 703340

Made In Turkey

IN

P

U

T

+

 

G

N

D

1

2

3

4

5

6

7

8

9 10 11 12

EI14

1

-24VAC

PROGRAMMABLE INDICATOR

ENDA

 

INDUSTRIAL ELECTRONICS

2

4

V

 A

C

 ±

1

0

%

5

0

/6

0

H

  

7

V

A

SN: XXXXXXXXX

8 680407 703364

Made In Turkey

IN

P

U

T

+

 

G

N

D

1

2

3

4

5

6

7

8

9 10 11 12

EI14

1

-SM

PROGRAMMABLE INDICATOR

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

8 680407 703388

Made In Turkey

9

-3

0

V

 

D

C

 

/

 7

-2

4

V

 A

C

±

1

0

%

  

7

V

A

 

EI141

-

E

-09-160217

2

/3

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18

ENDA

TM

TERMS

1)

 Measurement value, measurement unit, the minimum or the maximum measured values are 

    displayed in the run mode.
    Parameter name, parameter value or a user defined unit is displayed in the programming mode.

3)

 De

    Used for making the minimum and the maximum measured values equal in the run mode.

crement or parameter selection key in the programming mode.

2)

 Increment or parameter selection key in the programming mode.

    Used for displaying measurement unit or the max. measured value in the run mode.

4)

 Used for selecting run and programming modes,

displaying 

    measurement unit or making the minimum and the maximum measured values equal. 
 

 adjusting parameters, 

     4 digits  7 segment yellow LED display

  ( 2 ),( 3 ),( 4 ),( 5 ) Keypad

  ( 1 ) Digital display

12.5mm       

      Micro switch

         Character height

Panel cut-out

71,5mm

2

9

,5

m

m

 

Note :

  

1)

 Panel thickness should be maximum 7 mm.

2) 

There must be at least 60mm free space 

behind the device, otherwise it would be difficult to 
remove it from the panel.

DIMENSIONS

Flush mounting 

clamp

Panel

Depth

2

71mm

5mm

Flush mounting 

clamp

1

Rubber
packing

SET

SET

 EI141

ENDA

P

ROGRAMMABLE INDICATOR

3

5

m

m

77mm

For removing mounting clamps ;

 

Push flush mounting clamps in 

direction 

1

 as shown in the figure below. 

Then pull out the clamps in direction 

2

 .

IN

P

U

T

+

 

G

N

D

1

2

3

4

5

6

7

8

9

10

11

12

EI1

4

1

-2

30

VA

C

PR

OG

RA

MM

AB

LE

 IN

DIC

AT

OR

EN

DA

 

IN

DU

ST

RIA

L E

LE

CT

RO

NIC

S

2

3

0

V

 A

C

 +

1

0

%

 - 

2

0

%

5

0

/6

0

H

  7

V

A

SN

: X

XX

XX

XX

XX

86

80

40

77

03

34

0

Ma

de

 In

 T

urk

ey

Flush mounting 

clamp

1

2

2

CONNECTION DIAGRAM

ENDA EI141

 is intended for installation in control panels. Make sure that the device is used only for intended purpose. 

grounded on the instrument side. During an installation, all of the cables that are connected to the device must be free of electrical power. The 
device must be protected against inadmissible humidity, vibrations, severe soiling. Make sure that the operation temperature is not exceeded. 
All input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should not 
be close to the power cables or components. The installation and electrical connections must be carried out by a qualified staff and must be 
according to the relevant locally applicable regulations.  

The shielding must be 

2

1

184-253V AC 
50/60Hz 7VA

230V AC 
Supply

Switch

Cable size: 1,5mm²

Fuse

F 100 mA 

250V AC

Neutral

Line

SUPPLY :

NOTE :

Fuse should
be connected

1) Mains supply cords shall meet the requirements of  IEC 60227 or IEC 60245. 
2) In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument and it

 

should 

 

be easily accessible by the operator.

Note :

Holding screw
0.4-0.5Nm 

Equipment is protected throughout
by DOUBLE INSULATION.