SET
EI141
ENDA
P
ROGRAMMABLE INDICATOR
IN
P
U
T
+
G
N
D
1
2
3
4
5
6
7
8
9 10 11 12
EI14
1
-230VAC
PROGRAMMABLE INDICATOR
ENDA
INDUSTRIAL ELECTRONICS
2
3
0
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
7
V
A
SN: XXXXXXXXX
8 680407 703340
Made In Turkey
IN
P
U
T
+
G
N
D
1
2
3
4
5
6
7
8
9 10 11 12
EI14
1
-24VAC
PROGRAMMABLE INDICATOR
ENDA
INDUSTRIAL ELECTRONICS
2
4
V
A
C
±
1
0
%
5
0
/6
0
H
z
7
V
A
SN: XXXXXXXXX
8 680407 703364
Made In Turkey
IN
P
U
T
+
G
N
D
1
2
3
4
5
6
7
8
9 10 11 12
EI14
1
-SM
PROGRAMMABLE INDICATOR
ENDA
INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
8 680407 703388
Made In Turkey
9
-3
0
V
D
C
/
7
-2
4
V
A
C
±
1
0
%
7
V
A
EI141
-
E
-09-160217
2
/3
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah.
Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:18
ENDA
TM
TERMS
1)
Measurement value, measurement unit, the minimum or the maximum measured values are
displayed in the run mode.
Parameter name, parameter value or a user defined unit is displayed in the programming mode.
3)
De
Used for making the minimum and the maximum measured values equal in the run mode.
crement or parameter selection key in the programming mode.
2)
Increment or parameter selection key in the programming mode.
Used for displaying measurement unit or the max. measured value in the run mode.
4)
Used for selecting run and programming modes,
displaying
measurement unit or making the minimum and the maximum measured values equal.
adjusting parameters,
4 digits 7 segment yellow LED display
( 2 ),( 3 ),( 4 ),( 5 ) Keypad
( 1 ) Digital display
12.5mm
Micro switch
Character height
Panel cut-out
71,5mm
2
9
,5
m
m
Note :
1)
Panel thickness should be maximum 7 mm.
2)
There must be at least 60mm free space
behind the device, otherwise it would be difficult to
remove it from the panel.
DIMENSIONS
Flush mounting
clamp
Panel
Depth
2
71mm
5mm
Flush mounting
clamp
1
Rubber
packing
SET
SET
EI141
ENDA
P
ROGRAMMABLE INDICATOR
3
5
m
m
77mm
For removing mounting clamps ;
-
Push flush mounting clamps in
direction
1
as shown in the figure below.
Then pull out the clamps in direction
2
.
IN
P
U
T
+
G
N
D
1
2
3
4
5
6
7
8
9
10
11
12
EI1
4
1
-2
30
VA
C
PR
OG
RA
MM
AB
LE
IN
DIC
AT
OR
EN
DA
IN
DU
ST
RIA
L E
LE
CT
RO
NIC
S
2
3
0
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
7
V
A
SN
: X
XX
XX
XX
XX
86
80
40
77
03
34
0
Ma
de
In
T
urk
ey
Flush mounting
clamp
1
2
2
CONNECTION DIAGRAM
ENDA EI141
is intended for installation in control panels. Make sure that the device is used only for intended purpose.
grounded on the instrument side. During an installation, all of the cables that are connected to the device must be free of electrical power. The
device must be protected against inadmissible humidity, vibrations, severe soiling. Make sure that the operation temperature is not exceeded.
All input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should not
be close to the power cables or components. The installation and electrical connections must be carried out by a qualified staff and must be
according to the relevant locally applicable regulations.
The shielding must be
2
1
184-253V AC
50/60Hz 7VA
230V AC
Supply
Switch
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Neutral
Line
SUPPLY :
NOTE :
Fuse should
be connected
1) Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument and it
should
be easily accessible by the operator.
Note :
Holding screw
0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.