While holding key COMPRESSOR setpoint value appears and by using and keys
the value can be adjusted.
Running Mode
Process
Value
-
30.0
-
29.9
-
30.0
1000
If both keys are pressed and held for 3 seconds,
programming mode is entered.
-
22.0
If both keys are pressed,
run mode is entered.
Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode. While holding key, setpoint value of the selected parameter appears and by
using and keys the value can be adjusted.
When held down for 3 second in the run mode, manual defrost starts. After the specified time with
D.dur
parameter manual defrost finishes. When held down for 3 second manual defrost finishes before the
specified time ends. Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for increasing the setpoint value in the run mode
.
When held down for a few
seconds, the change rate accelerates.
When held down for 3 second in the run mode continuous mode (*) starts. After the specified time with
C.Con
parameter this mode finishes. When held down for 3 second continuous mode finishes before
the specified time ends. Used for selecting parameters and decreasing the setp
oint value
in the programming mode and for decreasing the setpoint value in the run mode
.
When held down for a few seconds,
the change rate accelerates.
DEFROST
LED
COMPRESSOR
LED
FAHRENHEIT
LED
Displayed process value in the run mode, parameter name or value in programming mode.
SET
SET
SET
SET
A.lol
A.uPl
A.Set
A.dpo
The lower limit
of the setpoint.
Delay time for the compressor
after power is on.
Defrost
ing duration.
Limit for lower alarm level.
Limit for upper alarm level
Alarm
configuration.
Energy was given the
message of alarm delayed
to show.
The upper limit
of the setpoint.
Delay time required for
compressor to restart following
a stop.
Compressor’s on the continuous
on mode length of stay
.
Refrigeration differential
(hysteresis).
In the probe failure,compressor’s
output on duration.
Refrigeration
offset
value.
Displ
ay resolution.
In the probe failure,compressor’s
output off duration.
D.dur
D.int
C.pon
C.ppn
C.Con
C.Fos
C.ppF
Interval between defrost
cycles.
Program
ming mode
R.lol
R.uPl
R.Hys
R.off
DrES
EDT1411P-
E
-0
1-R
Temperature unit.
Unit
D
uring the defrosting
display configuration.
D.dsp
D.drE
Delay time for display real
temperature after defrost
is over.
Defrosting the process of
energy and the start of.
D.Pon
D.dPo
Defrosting’s delayed starting
after power is on.
A.dFl
Situation of alarm after the
were formed alarm message
delayed to show.
A.HYS
Alarm diffrerential
(hysteresis).
Security parameter for compressor
control menu.
Security parameter for defrosting
control menu.
Security parameter for alarm
control menu.
Security parameter for refrigeration
set value.
A.
-
re
A.
-
al
A.
-
de
A.
-
Cp
A.rE.S.
Security parameter for refrigeration
menu.
RE
CP
DE
Al
SE
2/3
S.Cod
Access code for security menu.This
parameter should be
321
.
On the side on display at sight message,thermostat probe is short circuit or measured
temperature value is higher than the scale.
On the side on display at sight message, measured value is higher than the upper alarm
value.
Error Messages
On the side on display at sight message,measured value is lower than the lower alarm
value.
Alo
Ahi
Pfa
PsC
On the side on display at sight message,thermostat probe is broken or measured
temperature value is lower than the scale.