INPUT TYPES
4/5
EC762-E-06-R
Adjusting to a value between 0.1 and 999.9 seconds, a pulse output is obtained.
Adjusting to
0.0, a continuous output is obtained.
out
ti.
out
ti.
OUTPUT TYPES
Reset
999,999
Preset
0
Out
Reset
Reset
999,999
999,999
Preset
Preset
0
Out
0
Out
Reset
999,999
Preset
0
Out
Reset
999,999
Preset
0
Out
Reset
999,999
Preset
0
Out
Config
8
Config
9
Config
10
Out
Reset
999,999
Preset
0
-99,999
Out
Reset
999,999
Preset
0
-99,999
Out
Reset
999,999
Preset
0
-99,999
= , ,
= , ,
=
=
dirEct
oppos.
= , , ,
= , , ,
Countr.
dir.
Countr.
dir.
inPut
typE
inPut
typE
inPut
typE
inPut
typE
CP1
-
UP
CP2
-
dn
CP1
-
UP
CP2
-
dn
CP1
-
UP
CP2
-
UP
CP1
-
UP
CP2
-
UP
CP1
-
UP
CP2
-
Gt.
CP1
-
UP
CP2
-
Gt.
CP1
-
UP
CP2.dir.
CP1
-
UP
CP2.dir.
UP
Ph
-
4
UP
Ph
-
4
UP
-
dn
Ph
-
1
UP
-
dn
Ph
-
1
UP
-
dn
Ph
-
2
UP
-
dn
Ph
-
2
While counter value is
equal to preset value,
OUT becomes active.
While counter value is
lower or equal to the
preset value, OUT is
active.
While counter value is
greater or equal to the
preset value, OUT
is active.
Conf.
1
Conf.
2
Conf.
4
Conf.
5
Conf.
6
Conf.
7
(Autoreset and
Display hold)
(Delayed
Autoreset
and HOLD)
(Delayed
Autoreset )
(Autoreset )
(HOLD )
UP COUNTER
DOWN COUNTER
UP / DOWN COUNTER
ýnPut
tyPE
Countr.
dýr.
dýrEct.
CP1-UP
CP2-dn
CP1-UP
CP2-UP
UP
Ph-4
UP-dn
Ph-1
UP-dn
Ph-2
CP1-UP
CP2-Gt
CP1-UP
CP2.dýr
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
H
H
H
H
H
H
H
H
H
H
H
H
L
L
L
L
L
L
L
L
L
L
L
L
n
n
n
n
n
n
n
n+1
n+1
n+1
n+1
n+1
n+1
n+1
n+1
n+2
n+2
n+2
n+2
n+2
n+2
n+2
n+2
n+2
n+2
n+2
n+3
n+3
n+3
n+3
n+3
n+3
n+4
n+4
n+5
n+4
n+3
n+3
n+3
n+5
n+5
n+4
n+6
n+6
n+7
n+7
n+8
n+3
n+3
n+3
n+4
n+4
C o u n t
input CP2
C o u n t
input CP2
C o u n t
input CP2
C o u n t
input CP2
C o u n t
input CP2
Ga
t e
input CP2
DISPLAY
DISPLAY
DISPLAY
DISPLAY
DISPLAY
DISPLAY
C o u n t
input CP1
H
H
L
L
direction
input CP2
DISPLAY
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
H
H
H
H
H
H
H
H
H
H
H
H
L
L
L
L
L
L
L
L
L
L
L
L
n
n
n-1
n-1
n-1
n-2
n-2
n-2
n-2
n-3
n-3
n-3
n-4
n-4
n-5
C o u n t
input CP2
C o u n t
input CP2
C o u n t
input CP2
Ga
t e
input CP2
C o u n t
input CP2
C o u n t
input CP2
DISPLAY
DISPLAY
DISPLAY
DISPLAY
DISPLAY
DISPLAY
oPPoS.
C o u n t
input CP1
H
H
L
L
d i r c t i o n
input CP2
DISPLAY
n
n
n
n
n
n-1
n-1
n-1
n-1
n-1
n-2
n-2
n-2
n-2
n-2
n-2
n-2
n-3
n-3
n-3
n-4
n-3
n-3
n-3
n-4
n-5
n-5
n-6
n-6
n-7
n-7
n-8
n-3
n-4
n-3
n-4
Note: The maximum value of the input frequency can be
one half of the selected value (
inPut. Frq.
)
Note: The maximum value of the input frequency can be
one half of the selected value (
inPut. Frq.
)
Note: The maximum value of the input frequency can be
1/3 of the selected value (
inPut. Frq.
)
Note: The maximum value of the input frequency can be
2/3 of the selected value (
inPut. Frq.
)
For PNP sensor, counter is triggered at the rising edge of the pulses.
For NPN sensor, if you select
I
above diagram for
Cntr.dIr. DIrEct
replaces with
Cntr.dIr OPPo.
.
nPt.tyPE
CP1.U. CP2.r.
,
NOTE
:
For NPN sensor counter is triggered at the falling edge of the pulses.
1)
2)
Input frequency should not
exceed the values indicated
above. Otherwise, counter