LOW VOLTAGE TRANSFORMER INSTALLATION GUIDE

Encore Landscape Lighting

2277 Elliott Drive Troy, Michigan 48083

Website: www.encorelandscapelighting.com

Email:

[email protected]

Phone:

248-299-1919

Fax:

248-299-1911

4

INSTALL A PHOTOCELL:

Disconnect the source power to the transformer before installing the photo cell. Remove the rubber stopper
on the side of the transformer.

Remove the nut from the photo cell.

Unplug the jumper connection from the transformer.

Insert the wire and connector of the photo cell through the hole in the side of the transformer. Place the
nut around the wire and screw onto the photo cell, holding the unit in position.
Plug the photocell into the now empty socket connection.