ENCO Control  

Technical description 

 

Kulautuvos g. 45a , LT-47190 Kaunas

 

Tel. (+370 37) 360234 

Faks. (+370 37) 360358 

 

[email protected]  

 www.axis.lt 

 

SAFETY REQUIREMENTS

 

 
Before  operating  the 

controller  Enco  Control  (hereinafter   

device)

please  read  this  technical 

description  and  user's  manual  thoroughly  and  follow  their  instructions.  You  must  observe  all 
instructions for use that are enclosed with other components of system. 

Caution:  If  this  equipment  is  used  in  a  manner  not  specified  by  the  manufacturer,  the 

protection provided by the equipment may be impaired.

 

 

 

 

 
Enco Control device is a limited access area unit (It is intended for installation in 
the  cabinet).  The  device  complies  with  safety  class  II  with  an  additional 
grounding.  Power  supply  from  230  V  AC.  The  device  is  used  to  control  power 
circuits up to 230 V. 
It  is  necessary  to  follow  general  safety  requirements  during  installation  and 
maintenance process. To eliminate risk, only qualified technical personnel may 
install  and  maintain  devices  (certificates  for  electrical  installation  work  with 
equipment  up  to  1000  V  are  required).  Personnel  must  be  familiar  with 
appropriate technical documentation and general safety instructions.  

 

 

 

 
Before changing, repairing, connecting or disconnecting system parts  is 
required:  

(the switch is built-in the same cabinet as the 

controller);  

(electromagnetic actuators, pumps, actuators, etc.);  

to make sure that they are not powered. 

 

 

 

 
Protection of circuits of external battery is provided by fuse RXE185, 50V, 1.8A. 
Controller  does  not  protect  external  circuits  of  circulation  pumps  and  valve 
actuators.    It  is  necessary  to  use  additional  protection  circuits  to  protect 
circulation pumps and valve actuators against over current. 

 

 

 
Use  only  the  battery  specified  in  the  manufacturer's  instructions.  Using  other 
types of batteries may result in a fire or explosion hazard. 
It  is  recommended  use  the  instructions  and  recommendations  of  the  battery 
manufacturer when installing or replacing batteries. 

 

 
When the controller operating in the system, all devices of system for which it is 
provided  (required),  must  be  connected  to  the  protective  earth,  regardless  of 
their location in the system.  

 

 

 
To  protect  power  circuits  against  over  current,  short-circuit  or  fault  of 
grounding  of  primary  circuit  in  the  building  installation  must  be  installed 
automatic protective device - 2-pole circuit breaker (distance between contacts 
must be  

 = 3 mm). 

 

 
Only approved qualified technical personnel may install and maintain the device.  

Installation  and  maintenance  carry  out      not  qualified  personnel  is  strictly 
forbidden.

 

 

 
The  device  must  be  installed  in  a  locked  area  with  restricted  access  -  in  the 
electric  cabinet,  protection  class  IP65,  in  the  horizontal  position  on  DIN  rail 

Summary of Contents for Control

Page 1: ...ENCO Control Technical description Kulautuvos g 45a LT 47190 Kaunas Tel 370 37 360234 Faks 370 37 360358 info axis lt www axis lt 1 Universal controller ENCO Control Technical description Lithuania 2015 ...

Page 2: ...ed the switch is built in the same cabinet as the controller electromagnetic actuators pumps actuators etc to make sure that they are not powered Protection of circuits of external battery is provided by fuse RXE185 50V 1 8A Controller does not protect external circuits of circulation pumps and valve actuators It is necessary to use additional protection circuits to protect circulation pumps and v...

Page 3: ...ment should be protected against mechanical damage and shock Equipment should be stored in dry heated premises where environment temperature is not lower than 5 c o No aggressive chemical substances should be stored together because of corrosion hazard SWITCHING ON OFF Switch on the power Fig 1 The device is ready for operation Device status indicates LED1 Fig 2 Power is on the LED1 lights up and ...

Page 4: ...electing of the frequency period archiving from 1s Archiving of parameters technological process and variables in the heating system every 5 minutes to 7 days Sending of message if parameter value exceeds the limits up to 32 selected parameters Meter reading The controller can read all meters that support MBUS protocol Reading is performed Wild addresses There is a possibility to read out only one...

Page 5: ...nit MCU Microprocessor LCD Liquid Crystal Display SIM Subscriber identification module card RFID Radio frequency identification CN1 USB port RTC Real time clock DC Direct current AC Alternating current HVAC Heating ventilation and air conditioning systems Environmental conditions Ambient temperature 5 C 55 C Relative humidity Up to 93 Degree of protection of housing to IEC 60529 IP30 The device is...

Page 6: ...er of pressure measuring inputs 4 20 mA measurement channels 4 Number of temperature sensors 16 Communication modules and interfaces GPRS 900 1800 MHz 1 Ethernet 1 RS232 2 3 3V 1 RS485 1 Mbus CL 1 Card reader RFID 1 Screens displayed on LCD during operation are linked together and form well organized menu structure For convenience the screens are grouped into levels Review of menu items is perform...

Page 7: ...he controller 6 Outputs Inputs Review and control of status of Outputs Inputs 7 Connection state Status of communication systems 8 Set date time Setting up date and time 9 Lock configuration Lock possibility of configuration 1 HVAC system type selection The controller is capable of controlling different HVAC systems circuits 1 HVAC 1 HVAC 2 HVAC 3 HVAC 1 1 HVAC settings 1 HVAC type 1 1 1 HVAC type...

Page 8: ...on time of drive control 4 Transition Transition time period during which circuit gradually changeovers from one schedule to another 5 Integration Integration time 6 ECO temper Desired temperature for economic mode 7 NIGHT temper Desired night temperature 8 DAY temper Desired day temperature 9 Valves settings Settings of drive valve control address 10 Pump settings Settings of pump control address...

Page 9: ...dem settings 3 DHCP settings 4 Ping settings 5 NTP settings 6 Summer correct On 7 Reboot On 8 Reboot per 1440 9 UDP hello 37770 10 Device ID 1 11 Firmw Vers 1 16 12 FDate Apr 27 2012 13 FTime 15 41 31 You can select LAN or GPRS 2 1 Connect type 1 Ethr 2 GPRS If you use GPRS connection then you will need to set your modem settings Modem settings 2 2 Modem settings 1 Port settigs 2 GPRS ping On 3 GP...

Page 10: ...g period 4 IP Remote server s IP address if Ping does not take place with gateway Setting time synchronization of device via network 2 5 NTP settings 1 Check time Off 2 NTP interface Ethr 3 NTP period 1440 4 NTP port 123 5 IP 192 168 0 1 6 Time zone 2 Field Description 1 Check time Time synchronization On Off 2 NTP interface Communication interface to synchronize the time 3 NTP period Time synchro...

Page 11: ...P address DHW UDP hello Yes No 37770 3 settings for reading external devices meters 3 Modules 1 Module 2 Module 3 Module 4 Module 5 Module 6 Module 7 Enable connect On 8 Connect type Ethr 9 Connect prt 37777 10 Remote enable Off 11 IP 192 168 0 211 12 Remote port 37775 13 Connect per 3600 Select the required device type 3 1 Module 1 Type 3 1 1 Module 1 2 SKS 3 3 SKM 1 M 4 SKM 01M 5 SKU01 6 SKU01SF...

Page 12: ... 19200 8 38400 9 56700 10 115200 Set up parity It should be the same as stated on readout device settings 3 1 6 Parity 1 None 2 Odd 3 Even 4 Mark 5 Space Select database data archive wherein will be stored data collected from an external device 3 1 7 Array 1 0 2 1 3 2 4 3 Set up device address or number depending what applicable DHW Addr ID Yes No 254 Meter reading period DHW Period Yes No 3600 3 ...

Page 13: ...the number of sensors that have been found 3 T xx Shows temperature value of corresponding sensor It is possible to change the sensor number review and control of inputs outputs status 6 Outputs Inputs 1 Output0 2 Output1 3 Output2 4 Output3 5 Output4 6 Output5 7 Output6 8 Output7 9 Output8 10 Input0 11 Input1 12 Input2 13 Input3 14 Input4 15 Input5 16 Input6 The black dot inside the circle means ...

Page 14: ... Selecting of the frequency period archiving from 1s Archiving of parameters technological process and variables in the heating system every 5 minutes to 7 days Sending of message if parameter value exceeds the limits up to 32 selected parameters The controller can read all meters that support MBUS protocol Reading is performed Wild card search algorithm The data from the meters can be read out to...

Page 15: ...Figure 20 Figure 21 The necessary switches must be provided during the installation distance between switches contacts must be 3 mm With which you can turn off the power supply It is recommended to establish the device in the same cabinet as the switches for cutting off power supply The switches should be adjusted for the power used by the equipment max 15VA Connection cables must comply with IEC ...

Page 16: ...s 370 37 360358 info axis lt www axis lt 16 Numbering of terminals 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 LCD GPRS modem CN1 J28 J27 J29 J21 R F SIM PSU ...

Page 17: ...iscrete input 2 10 m 17 Discrete input 2 18 D3 D3 Discrete input 3 10 m 19 Discrete input 3 20 15 V 100 mA max GND Ground 10 m 21 V Power supply output for external devices z 10 m 22 RFID Antenna R1 Antenna RFID 0 3 m 23 R2 24 T sensor GND GND for digital temperature sensors 70 m 25 DATA Signal terminal for digital temperature sensors 70 m 26 5 V 5 V power supply voltage for digital temperature se...

Page 18: ... R 3 m 43 D4 44 15 V 100 mA max V Power supply for external devices 10 m 45 GND Ground 10 m 46 Discrete inputs D5 D6 0 3 V 10 mA max D 5 Discrete input 5 0 3V Rin 100 R 3 m 47 48 GND Ground 10 m 49 D 6 Discrete input 6 0 3V Rin 100 R 3 m 50 51 Semiconductor relays NO O0 O5 230 V 50Hz 1 2A each Total current for all relays 4 A Max O5 O5 Power output 5 3 m 52 53 O4 O4 Power output 4 3 m 54 55 O3 O3 ...

Page 19: ...2 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 J28 J27 J21 J29 PSU 230V Enco Control DIN0 DIN1 DIN2 DIN3 б Power is supplied from the external DC voltage 24 V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 J28 J27 J21 J29 PSU 230V Enco Cont...

Page 20: ...0R 100R 5V 100R 100R M BUS device connection 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 J28 J27 J21 J29 PSU 230V Enco Control GND GND A1 A3 A2 V A0 M BUS device M BUS device Pressure sensors wiring diagram 4 sensors 4 20 мА 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ...

Page 21: ... control output connection 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 J28 J27 J21 J29 Enco Control Out 0 Out 1 Out 2 Out 3 Out 4 Out 5 Out 8 Out 7 Out 6 M1 M2 M3 SF4 SF5 SF6 230 N 230 L SF1 SF2 SF3 V1 V2 V3 ...

Page 22: ...Kulautuvos g 45a LT 47190 Kaunas Tel 370 37 360234 Faks 370 37 360358 info axis lt www axis lt 22 Wiring diagram for connecting of the temperature sensors and RFID antennas 22 24 23 26 25 T0 T1 T2 T3 T15 Blue Brown Yellow RF ID T sensor ...

Page 23: ...mber Description Serial interface connector J28 type RJ11 J28 1 Port 1 signal TX RS232 J28 2 Port 1 GND J28 3 Port 1 signal RX RS232 J28 4 Port 2 GND J28 5 Port 2 TX TTL J28 6 Port 2 RX TTL Serial interface connector J27 type RJ11 J27 1 Port 0 signal TX RS232 J27 2 Port 0 GND J27 3 Port 0 signal RX RS232 J27 4 J27 5 J27 6 Expansion connector J29 type RJ11 J29 1 J29 2 GND J29 3 J29 4 GND J29 5 RS48...

Page 24: ...ENCO Control Technical description Kulautuvos g 45a LT 47190 Kaunas Tel 370 37 360234 Faks 370 37 360358 info axis lt www axis lt 24 Enco Control into the cabinet with the opened first transparent door ...

Page 25: ...description Kulautuvos g 45a LT 47190 Kaunas Tel 370 37 360234 Faks 370 37 360358 info axis lt www axis lt 25 AB Axis Industries Kulautuvos g 45a LT 47190 Kaunas Lithuania Tel 370 37 36 02 34 Faks 370 37 36 03 58 info axis lt ...

Reviews: