Users’ Manual
ESM-12S Digital seepage monitoring system
Page
|
17
6.2 Configuration of ESDL-30 datalogger with ESM-12S sensor with Modbus output
Default Settings for ESM-12S sensor with Modbus output
Sensor default settings are given below
Device address
0x01
Baud rate
115200
Data
8-bit
Stop bit
1
Parity
None
Endian
Big Endian Atomic 16
Measuring time
1 Sec
A brief on connection and configuration for model ESM-12S sensor with SDI-12 output is given below.
1. Double click the ESDL-30 datalogger software icon on the Desktop. The main screen of the application
appears as displayed in figure below
2. Connecting Datalogger: Click “Datalogger” followed by “Connect/Disconnect Datalogger”. A
“Connection” window will appear as shown below. Select the usable “Com port” and then click
“Connect”. The progress bar appears on the screen as the application takes few seconds to get
connected.
3. After successful connection, information message pops up on the screen confirming successful
connection. Press “OK” to proceed. This will change “Connection Status”, at the left bottom, from Red
to Green.