en
7.9 MAINTENANCE OF THE VIBRATING ASSEMBLY
Check the oil level every 50 hours’ operation of the plate. Place the equipment on a flat horizontal
surface. Unscrew the oil cap with its washer. If the oil level is below the thread add oil and screw
the oil cap back on.
Replace the oil every 300 hours’ operation. Empty the oil out of the vibrating assembly by
unscrewing the oil cap; then tilt the plate and pour the oil into a container. Take the oil to a used oil
collection spot.
Place the equipment on a flat horizontal surface. Add approximately 210 c.c. oil SEA 10W/40 until
the oil drips through the thread of the drainage hole and screw the oil cap back on again.
7.10 STORAGE
When storing the plate for a long period of time:
7.10.1.
Completely empty the fuel from the tank, the fuel pipe and the carburettor.
7.10.2.
Remove the spark plug and pour a few drops of oil into the cylinder. Turn the engine
several times by hand so that the oil spreads over the inner surface of the cylinder.
7.10.3.
Clean the outer surface of the machine with a cloth soaked in oil. Cover the unit and keep
it out of the damp and in a dust-free environment.
7.11 TROUBLESHOOTING
PETROL ENGINE
Does not start:
- There is fuel but the spark plug does not spark
•
There is electricity in the high-voltage cable
There is electricity in the high-voltage cable
Bridged ignitor plug
Carbon deposit in ignitor plug
Short circuit due to faulty insulation of ignitor plug
Electrodes separated incorrectly
•
There is no electricity in the high-voltage cable
Short circuited stop button switch
Faulty ignition coil
Condenser insulation faulty or short-circuited
Ignition coil broken or short-circuited
•
Satisfactory compression
Incorrect fuel
Water or dust has got in
Faulty air filter
- There is fuel and the ignitor plug sparks
•
Faulty compression
Inlet or outlet valve stuck or faulty
Piston ring or cylinder worn
Cylinder head or ignitor plug incorrectly adjusted
VIBRATING PLATES
20
PEN10B-PEN13C-PEN16C-PEN16D